Application of Balloon-Expandable Transcatheter Heart Valve in Bicuspid Aortic Valve.

JACC Asia

Department of Cardiology, University Hospital of Zurich, University of Zurich, Zurich, Switzerland.

Published: September 2021

Bicuspid aortic valve (BAV) remains challenging in transcatheter aortic valve replacement (TAVR) because of unfavorable anatomy. New-generation balloon-expandable valve (BEV) appears to be a valid alternative to surgery, especially in some Asian countries with a higher prevalence of BAV. This tutorial review summarizes current thinking about how to plan and implant BEV in BAVs using versatile techniques. First, the authors depict the main morphological characteristics of BAVs and their effects on the TAVR procedure. Next, the authors provide preprocedural analysis on sizing, obtaining the optimal deployment projection, and how to simplify valve-crossing. Finally, the authors provide step-by-step guidance on how to deploy the BEVs with evolved iterations in terms of specific anatomies, calcified annulus, and giant annulus.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9627836PMC
http://dx.doi.org/10.1016/j.jacasi.2021.07.012DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
valve bicuspid
8
bicuspid aortic
8
authors provide
8
valve
5
application balloon-expandable
4
balloon-expandable transcatheter
4
transcatheter heart
4
heart valve
4
valve bav
4

Similar Publications

Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.

Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.

View Article and Find Full Text PDF

Background: Transcatheter aortic valve replacement (TAVR) is a well-established treatment option for patients with severe aortic valve stenosis; however, clinical valve thrombosis is a major challenge.

Case Summary: A 92-year-old woman underwent TAVR for severe aortic stenosis. One month later, the patient developed acute heart failure.

View Article and Find Full Text PDF

We report a 75-year-old female with a history of two heart operations: aortic valve replacement (St. Jude Medical 21 mm) at the age of 44 years for severe rheumatic aortic stenosis and mitral valve replacement (Carbomedics 29 mm) at the age of 51 years for rheumatic mitral regurgitation. Decades later, she presented with exertional dyspnea.

View Article and Find Full Text PDF

Introduction The study aimed to retrospectively evaluate the early patient outcome and left ventricular function after mitral valve replacement with a tilting disc valve and total preservation. Patients and methods This retrospective observational study includes patients who underwent mitral valve replacement using a tilting disc valve with total preservation of mitral valvular and subvalvular apparatus from July 2021 to August 2022 at a single center. Results The data were reviewed retrospectively for age, sex, comorbidities, operating time, aortic cross-clamp time, cardiopulmonary bypass time, preoperative and postoperative left ventricular ejection fraction, mean gradient across the mitral valve, left ventricular diameter, left atrial size, atrial fibrillation, complications, mortality, and early patient outcome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!