Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study.

Z Med Phys

Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland; Geneva Neuroscience Center, Geneva University, Geneva, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.

Published: August 2024

Purpose: The most common detector material in the PC CT system, cannot achieve the best performance at a relatively higher photon flux rate. In the reconstruction view, the most commonly used filtered back projection, is not able to provide sufficient reconstructed image quality in spectral computed tomography (CT). Developing a triple-source saddle-curve cone-beam photon counting CT image reconstruction method can improve the temporal resolution.

Methods: Triple-source saddle-curve cone-beam trajectory was rearranged into four trajectory sets for simulation and reconstruction. Projection images in different energy bins were simulated by forward projection and photon counting CT respond model simulation. After simulation, the object was reconstructed using Katsevich's theory after photon counts correction using the pseudo inverse of photon counting CT response matrix. The material decomposition can be performed based on images in different energy bins.

Results: Root mean square error (RMSE) and structural similarity index (SSIM) are calculated to quantify the image quality of reconstruction images. Compared with FDK images, the RMSE for the triple-source image was improved by 27%, 21%, 14%, 8%, and 6% for the reconstrued image of 20-33, 33-47, 47-58, 58-69, 69-80 keV energy bin. The SSIM was improved by 1.031%, 0.665%, 0.396%, 0.235%, 0.174% for corresponding energy bin. The decomposition image based on corrected images shows improved RMSE and SSIM, each by 33.861% and 0.345%. SSIM of corrected decomposition image of iodine reaches 99.415% of the original image.

Conclusions: A new Triple-source saddle-curve cone-beam PC CT image reconstruction method was developed in this work. The exact reconstruction of the triple-source saddle-curve improved both the image quality and temporal resolution.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11384087PMC
http://dx.doi.org/10.1016/j.zemedi.2022.10.003DOI Listing

Publication Analysis

Top Keywords

triple-source saddle-curve
20
saddle-curve cone-beam
16
photon counting
16
image reconstruction
12
image quality
12
image
10
cone-beam photon
8
counting image
8
reconstruction method
8
images energy
8

Similar Publications

Triple-source saddle-curve cone-beam photon counting CT image reconstruction: A simulation study.

Z Med Phys

August 2024

Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, Switzerland; Geneva Neuroscience Center, Geneva University, Geneva, Switzerland; Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands; Department of Nuclear Medicine, University of Southern Denmark, Odense, Denmark.

Purpose: The most common detector material in the PC CT system, cannot achieve the best performance at a relatively higher photon flux rate. In the reconstruction view, the most commonly used filtered back projection, is not able to provide sufficient reconstructed image quality in spectral computed tomography (CT). Developing a triple-source saddle-curve cone-beam photon counting CT image reconstruction method can improve the temporal resolution.

View Article and Find Full Text PDF

Exact image reconstruction with triple-source saddle-curve cone-beam scanning.

Phys Med Biol

May 2009

Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, People's Republic of China.

In this paper, we propose an exact shift-invariant filtered backprojection (FBP) algorithm for triple-source saddle-curve cone-beam CT. In this imaging geometry, the x-ray sources are symmetrically positioned along a circle, and the trajectory of each source is a saddle curve. Then, we extend Yang's formula from the single-source case to the triple-source case.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!