Connector design effects on the in vitro fracture resistance of 3-unit monolithic prostheses produced from 4 CAD-CAM materials.

J Prosthet Dent

Associate Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea. Electronic address:

Published: December 2022

Statement Of Problem: Studies that compared the fracture strength of monolithic lithium disilicate and 5-mol% yttria partially stabilized zirconia multiunit fixed dental prostheses are sparse.

Purpose: As the connector is the weakest part of a fixed dental prosthesis, the purpose of this in vitro study was to investigate the effect of connector designs and material on the fracture strength of 3-unit monolithic fixed dental prostheses.

Material And Methods: Resin-ceramic canine and premolar teeth (N=144) were prepared for fixed dental prosthesis abutments. Prostheses with 3 connector designs (width=height, widthheight) were made from 2 types of lithium disilicate (IPS e.max CAD and Amber Mill) and 5-mol% yttria partially stabilized zirconia (3M Lava Esthetic and Katana Zirconia UTML). Fracture strengths were measured after 200 000 cycles of dynamic loading of 50 N and thermocycling at 5 °C and 55 °C, and the fracture patterns were analyzed. Two-way analysis of variance and the Fisher exact test were used for statistical analysis (α=.05).

Results: The material and connector design affected the fracture strength of fixed dental prostheses (P<.05), and a significant interaction was found between the material and connector design (P<.05). The IPS e.max CAD material had significantly lower fracture strength than Amber Mill, 3M Lava Esthetic, or Katana Zirconia UTML (P<.05). Connector designs with a greater width versus height showed significantly lower fracture strengths than other designs (P<.05).

Conclusions: The connector design of 3-unit fixed dental prostheses, particularly the connector height, may affect fracture strength depending on the prosthesis material.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2022.09.018DOI Listing

Publication Analysis

Top Keywords

fixed dental
20
fracture strength
12
connector design
8
3-unit monolithic
8
lithium disilicate
8
5-mol% yttria
8
yttria partially
8
partially stabilized
8
stabilized zirconia
8
dental prostheses
8