A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effect of hematocrit, galactose and ascorbic acid on the blood glucose readings of three point-of-care glucometers. | LitMetric

Glucometers are commonly used in a variety of healthcare settings and use in critically ill patients should not be assumed without appropriate tool validation. The study objective was to evaluate the accuracy of three point-of-care glucometers (POCGs) to assess glucose concentration in human blood sample. The POCGs tested included three different instruments and utilized three factors (hematocrit [Hct], galactose and ascorbic acid) in glucose measurements to determine the glucometers' accuracy and compared to the reference laboratory biochemical analyzer (Cobs 8000, Roche, Basal, Switzerland). In this study, the Nova StatStrip glucometer showed no significant variation compared to the laboratory method at high glucose level with various Hct%. ACCU-Chek Inform II overestimated the glucose results at Hct 22% and underestimated at Hct 62%. The Freestyle glucometer showed lower glucose levels compared to the Cobas 8000 at Hct 62%. The ACCU-Check showed significant increase of blood glucose with low Hct% levels when compared to the laboratory method. The Freestyle showed a decreased level of glucose with high Hct 62% interference compared to the Cobas 8000. Galactose interference 100 and 200 mg/dL dramatically affected the accuracy of ACCU-Chek Inform II. Nevertheless, among all three POCGs in this study, the Nova StatStrip showed the most reliable and stable results for glucose level in the presence of interference. Especially, those in critical care units, whereas the Freestyle Precision Pro and ACCU-Chek Inform II were insufficiently accurate for critically ill patients.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00365513.2022.2138779DOI Listing

Publication Analysis

Top Keywords

accu-chek inform
12
hct 62%
12
glucose
9
galactose ascorbic
8
ascorbic acid
8
blood glucose
8
three point-of-care
8
point-of-care glucometers
8
critically ill
8
ill patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!