Background: Carotid atherosclerosis is a major cause of stroke, traditionally diagnosed late. Positron emission tomography/computed tomography (PET/CT) with F-sodium fluoride (NaF) detects arterial wall micro-calcification long before macro-calcification becomes detectable by ultrasound, CT or magnetic resonance imaging. However, manual PET/CT processing is time-consuming and requires experience. We compared a convolutional neural network (CNN) approach with manual segmentation of the common carotids.
Methods: Segmentation in NaF-PET/CT scans of 29 healthy volunteers and 20 angina pectoris patients were compared for segmented volume (Vol) and mean, maximal, and total standardized uptake values (SUVmean, SUVmax, and SUVtotal). SUVmean was the average of SUVmeans within the VOI, SUVmax the highest SUV in all voxels in the VOI, and SUVtotal the SUVmean multiplied by the Vol of the VOI. Intra and Interobserver variability with manual segmentation was examined in 25 randomly selected scans.
Results: Bias for Vol, SUVmean, SUVmax, and SUVtotal were 1.33 ± 2.06, -0.01 ± 0.05, 0.09 ± 0.48, and 1.18 ± 1.99 in the left and 1.89 ± 1.5, -0.07 ± 0.12, 0.05 ± 0.47, and 1.61 ± 1.47, respectively, in the right common carotid artery. Manual segmentation lasted typically 20 min versus 1 min with the CNN-based approach. Mean Vol deviation at repeat manual segmentation was 14% and 27% in left and right common carotids.
Conclusions: CNN-based segmentation was much faster and provided SUVmean values virtually identical to manually obtained ones, suggesting CNN-based analysis as a promising substitute of slow and cumbersome manual processing.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10100011 | PMC |
http://dx.doi.org/10.1111/cpf.12793 | DOI Listing |
Sensors (Basel)
January 2025
Department of Architectural Engineering, Dankook University, 152 Jukjeon-ro, Yongin-si 16890, Republic of Korea.
In the construction industry, ensuring the proper installation, retention, and dismantling of temporary structures, such as jack supports, is critical to maintaining safety and project timelines. However, inconsistencies between on-site data and construction documentation remain a significant challenge. To address this, this study proposes an integrated monitoring framework that combines computer vision-based object detection and document recognition techniques.
View Article and Find Full Text PDFSensors (Basel)
January 2025
School of Biomedical Engineering, Tsinghua University, Shuang Qing Road, Beijing 100084, China.
Mastoidectomy is critical in acoustic neuroma surgery, where precise planning of the bone milling area is essential for surgical navigation. The complexity of representing the irregular volumetric area and the presence of high-risk structures (e.g.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Space Robotics Research Group (SpaceR), Interdisciplinary Centre for Security, Reliability and Trust (SnT), University of Luxembourg, L-1855 Luxembourg, Luxembourg.
Malaria remains a global health concern, with 249 million cases and 608,000 deaths being reported by the WHO in 2022. Traditional diagnostic methods often struggle with inconsistent stain quality, lighting variations, and limited resources in endemic regions, making manual detection time-intensive and error-prone. This study introduces an automated system for analyzing Romanowsky-stained thick blood smears, focusing on image quality evaluation, leukocyte detection, and malaria parasite classification.
View Article and Find Full Text PDFJ Clin Med
January 2025
Ophthalmology Section, Department of Medicine and Surgery, University of Perugia, 06132 Perugia, Italy.
To report the cosmetic, clinical, and visual outcomes of a combined surgical approach for treating a corneal/limbal dermoid using excision and a three-layered amniotic membrane graft with fibrin glue. An 18-year-old female presented with impaired vision and ocular discomfort caused by a prominent dome-shaped limbal congenital dermoid on the inferotemporal cornea, resulting in a significant aesthetic concern. A full assessment, including refraction, best-corrected visual acuity (BCVA), corneal topography, aberrometry and anterior segment OCT (AS-OCT) was conducted to plan the surgical approach.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Radiology, Weill Cornell Medicine, New York, NY 10022, USA.
: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!