A novel Nanocellulose-Gelatin-AS-IV external stent resists EndMT by activating autophagy to prevent restenosis of grafts.

Bioact Mater

Department of Cardiac Surgery, The First Affiliated Hospital of USTC, Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, Anhui, 230001, China.

Published: April 2023

Vein grafts are widely used for coronary artery bypass grafting and hemodialysis access, but restenosis remains the "Achilles' heel" of these treatments. An extravascular stent is one wrapped around the vein graft and provides mechanical strength; it can buffer high arterial pressure and secondary vascular dilation of the vein to prevent restenosis. In this study, we developed a novel Nanocellulose-gelatin hydrogel, loaded with the drug Astragaloside IV (AS-IV) as an extravascular scaffold to investigate its ability to reduce restenosis. We found that the excellent physical and chemical properties of the drug AS-IV loaded Nanocellulose-gelatin hydrogel external stent limit graft vein expansion and make the stent biocompatible. We also found it can prevent restenosis by resisting endothelial-to-mesenchymal transition (EndMT) . It does so by activating autophagy, and AS-IV can enhance this effect both and . This study has added to existing research on the mechanism of extravascular stents in preventing restenosis of grafted veins. Furthermore, we have developed a novel extravascular stent for the prevention and treatment of restenosis. This will help optimize the clinical treatment plan of external stents and improve the prognosis in patients with vein grafts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9615139PMC
http://dx.doi.org/10.1016/j.bioactmat.2022.10.013DOI Listing

Publication Analysis

Top Keywords

prevent restenosis
12
external stent
8
endmt activating
8
activating autophagy
8
vein grafts
8
extravascular stent
8
developed novel
8
nanocellulose-gelatin hydrogel
8
restenosis
7
stent
5

Similar Publications

Modification of polylactic acid (PLA) is a promising strategy for the next generation of bioresorbable vascular stent biomaterials. With this focus, FeMOFs nanoparticles was incorporated in PLA, and then post loading of carbon monoxide (CO) was performed by pressurization. It showed FeMOFs incorporation increased hydrophilicity of the surface and CO loading, and CO release was sustained at least for 3 days.

View Article and Find Full Text PDF

Comparison of Gensini score and SYNTAX score for predicting in-stent restenosis in patients with coronary artery disease and drug-eluting stent implantation.

Sci Rep

January 2025

State Key Laboratory of Pathogenesis, Prevention and Treatment of High Incidence Diseases in Central Asia, Department of Cardiology, Clinical Medical Research Institute, First Affiliated Hospital of Xinjiang Medical University, Xinjiang Medical University, 137 Liyushan Road, Urumqi, 830011, China.

The present study was aimed to investigate whether Gensini score or SYNTAX score was a valuable tool to predict in-stent restenosis (ISR) in coronary artery disease (CAD) patients with drug-eluting stents (DES) implantation. A retrospective case-control study and a validating retrospective cohort study were designed. All subjects' information was collected from the First Affiliated Hospital of Xinjiang Medical University.

View Article and Find Full Text PDF

Baicalin-based composite coating for achieving biological multifunctionality of vascular stents.

J Control Release

January 2025

Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu 610031, PR China. Electronic address:

Article Synopsis
  • Vascular stents are crucial for treating atherosclerosis and have reduced mortality through bare metal and drug-eluting options, but concerns like restenosis and thrombus formation persist.
  • Hyaluronic acid (HA) is often used to modify stent surfaces, but its effectiveness is limited due to degradation by reactive oxygen species (ROS) and enzymes, which can provoke inflammation and affect stent performance.
  • The study introduces a new coating using baicalin (BCL) to protect HA from degradation, offering enhanced endothelial cell support and greater stability, positioning this method as a promising advancement in stent technology.
View Article and Find Full Text PDF

Objectives: The primary objective of this case series is to assess the effectiveness of the off-label use of the PROPEL drug-eluting stent, traditionally FDA-approved for sinus surgery, in preventing restenosis following canalplasty in patients with chronic otologic conditions or congenital anomalies. The stent provides both mechanical support to maintain canal patency and localized steroid delivery to reduce inflammation and scarring.

Methods: Four patients with various otologic conditions underwent canalplasty, followed by the placement of drug-eluting stents into the external auditory canal.

View Article and Find Full Text PDF

Background And Objectives: Congenital choanal atresia is a rare condition that occurs in approximately 1 in 7,000 to 8,000 live births and involves the obstruction of the posterior nasal airway. It may present as either unilateral or bilateral, with bilateral cases being more severe due to the risk of immediate neonatal respiratory distress. Bilateral congenital choanal atresia (BCCA) necessitates prompt medical intervention to prevent cyanosis and significant breathing difficulties.

View Article and Find Full Text PDF