Background: Percutaneous left atrial appendage occlusion (LAAO) is an accepted alternative to thromboprophylaxis in patients with atrial fibrillation (AF) who are: (i) intolerant to oral anticoagulation (OAC) (e.g. life-threatening haemorrhage), (ii) non-adherent to OAC, or (iii) at a high bleeding risk with OAC. Improvement in LA mechanics was shown post-LAAO in the LAFIT-LARIAT study, using the Lariat device. No significant change was seen in LA mechanics after LAAO with the Watchman device in the LAFIT-Watchman study. The impact of LAAO with the Amplatzer or Amulet device on LA deformation mechanics has not been investigated.

Purpose: To evaluate the impact of LAAO with the Amplatzer or Amulet device on echocardiographic LA deformation indices.

Methods: All patients undergoing percutaneous LAAO from 2013 to 2021 at a single centre were included from an ongoing clinical registry. LA reservoir (ε), conduit (ε) and contractile strain (ε) and strain rate (SR, SR, SR) were assessed with two-dimensional speckle tracking echocardiography from an apical four-chamber view. Conduit and contractile strain and strain rates were only recorded for patients without AF at the time of echocardiography. Changes in LA deformation indices over time were compared with a linear mixed model.

Results: 28 LAAO recipients (mean age 73 ± 12 years, 68% male) were analysed. 5 (18%) patients had AF pre- or post-procedure. After a mean follow-up of 1.6 ± 1.4 months, the mean LA ε increased from 10.15 ± 6.44% to 10.18 ± 8.72% (p = 0.985), the mean LA ε increased from 5.12 ± 5.48% to 5.31 ± 6.11% (p = 0.891) and the mean LA ε decreased from 5.14 ± 4.32% to 4.95 ± 5.30% (p = 0.898). During the same time interval, the mean LA SR decreased from + 0.54 ± 0.23.s to + 0.48 ± 0.43.s (p = 0.566), the mean LA SR remained stable: -0.47 ± 0.41.s to -0.47 ± 0.32.s (p = 0.997) and the mean LA SR decreased from - 0.66 ± 0.50.s to -0.55 ± 0.46.s (p = 0.660).

Conclusion: No significant improvement in LA mechanical function was seen after LAAO with the Amplatzer or Amulet device. Different LAAO devices therefore appear to have divergent effects on LA deformation, the clinical implications of which may warrant further study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10554-022-02741-6DOI Listing

Publication Analysis

Top Keywords

left atrial
12
laao amplatzer
12
amplatzer amulet
12
amulet device
12
percutaneous left
8
atrial appendage
8
appendage occlusion
8
deformation indices
8
laao
8
impact laao
8

Similar Publications

Automated Classification of Cardiac Arrhythmia using Short-Duration ECG Signals and Machine Learning.

Biomed Phys Eng Express

January 2025

Electronics and Communication Engineering, Rajiv Gandhi University, Rono Hills, Doimukh, ITANAGAR, Itanagar, Arunachal Pradesh, 791112, INDIA.

Accurate detection of cardiac arrhythmias is crucial for preventing premature deaths. The current study employs a dual-stage Discrete Wavelet Transform (DWT) and a median filter to eliminate noise from ECG signals. Subsequently, ECG signals are segmented, and QRS regions are extracted for further preprocessing.

View Article and Find Full Text PDF

Obscurin is a giant protein that coordinates diverse aspects of striated muscle physiology. Obscurin immunoglobulin domains 58/59 (Ig58/59) associate with essential sarcomeric and Ca2+ cycling proteins. To explore the pathophysiological significance of Ig58/59, we generated the Obscn-ΔIg58/59 mouse model, expressing obscurin constitutively lacking Ig58/59.

View Article and Find Full Text PDF

Risk factors for the recurrence of atrial fibrillation after catheter ablation: a meta-analysis.

Egypt Heart J

January 2025

Department of Cardiology, Lianyungang No 1 People's Hospital, No. 6 East Zhenhua Road, Haizhou District, Lianyungang, 222061, Jiangsu, China.

Background: The rate at which atrial fibrillation (AF) patients experience a return of symptoms after catheter ablation is significant, and there are multiple risk factors involved. This research intends to perform a meta-analysis to explore the risk factors connected to the recurrence of AF in patients following catheter ablation.

Methods: The PubMed, Cochrane Library, WOS, Embase, SinoMed, CNKI, Wanfang, and VIP databases were explored for studies from January 1, 2000 to August 10, 2021, and research meeting the established inclusion requirements was chosen.

View Article and Find Full Text PDF

The Role of RyR2 Mutations in Congenital Heart Diseases: Insights Into Cardiac Electrophysiological Mechanisms.

J Cardiovasc Electrophysiol

January 2025

Department of Cardiology, Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, Beijing, China.

Ryanodine receptor 2 (RyR2) protein, a calcium ion release channel in the sarcoplasmic reticulum (SR) of myocardial cells, plays a crucial role in regulating cardiac systolic and diastolic functions. Mutations in RyR2 and its dysfunction are implicated in various congenital heart diseases (CHDs). Studies have shown that mutations in the RYR2 gene, which encodes the RyR2 protein, are linked to several cardiac arrhythmias, including catecholaminergic polymorphic ventricular tachycardia (CPVT), long QT syndrome (LQTS), calcium release deficiency syndrome (CRDS), and atrial fibrillation (AF).

View Article and Find Full Text PDF

Background: Historically, percutaneous transcatheter left atrial appendage closure (LAAC) has been performed under general anesthesia (GA) with transesophageal echocardiographic images obtained by a noninvasive cardiologist and usually requires an overnight hospital stay. Alternatively, we present our single-center experience performing LAACs under deep sedation (DS), employing an echocardiographic technician instead of a noninvasive cardiologist, and expediting same-day discharge. Mid- to long-term outcomes were also evaluated with follow-up imaging at a 45-day visit.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!