Background: We report a 62-year-old patient who received redo-orthotopic heart transplantation due to worsening severe aortic regurgitation after 19 months of continuous flow left ventricular assist device  (LVAD) (cf-LVAD) and temporary right ventricular assist device (RVAD) support for 1 month.

Case Report: The patient received a heartware LVAD (heartware ventricular assist device) and annuloplasty of the tricuspid valve due to end-stage heart failure (as a consequence of dilated cardiomyopathy) and severe tricuspid regurgitation in addition to right-sided extracorporeal membrane oxygenation (ECMO) implantation. Postoperatively due to the inability to wean the implanted ECMO, a temporary RVAD was implanted after which the patient's condition improved so that it had been explanted later and the patient was discharged after 9 months. In immediate postoperative echo, minimal aortic regurgitation was noted but in the follow-up transthoracic echocardiograms, there was a gradual increase in the severity of aortic regurgitation with worsening both right and left ventricular functions. Transcatheter aortic valve implantation was not an option due to unfavorable anatomical issues. That's why the patient was listed for urgent heart transplantation, performed 19 months after the LVAD implantation. The postoperative course was complicated due to acute renal failure. After recompensation, dialysis, and intensive physiotherapy, the patient could be discharged home after 3 months.

Conclusion: Severe aortic regurgitation is a recognizable complication after cf-LVAD implantation which in our case was managed successfully with orthotopic heart transplantation in this high-risk patient.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocs.17092DOI Listing

Publication Analysis

Top Keywords

aortic regurgitation
20
heart transplantation
16
severe aortic
12
ventricular assist
12
transplantation high-risk
8
high-risk patient
8
lvad implantation
8
temporary rvad
8
rvad support
8
patient received
8

Similar Publications

Chromosomal Location and Identification of as a New Gene Responsible for Familial Bicuspid Aortic Valve.

Diagnostics (Basel)

March 2025

Department of Cardiovascular Surgery, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China.

Congenital bicuspid aortic valve (BAV) signifies the most frequent category of congenital cardiovascular anomaly globally, occurring in approximately 0.5-2% of the general population worldwide. BAV is a major cause of thoracic aortopathy, encompassing aortic stenosis, aortic root dilation with regurgitation, aortic dissection, and aortic aneurysms, consequently leading to substantial late-onset morbidity and mortality.

View Article and Find Full Text PDF

Background: The use of transcatheter aortic valve implantation (TAVI) for severe aortic stenosis is expanding to patients across the entire spectrum of surgical risk. We aimed to perform a meta-analysis comparing TAVI and surgical aortic valve replacement (SAVR) in trials enrolling lower risk patients.

Methods: We conducted a meta-analysis of randomized controlled trials (RCTs) comparing safety and efficacy outcomes between TAVI and SAVR among lower risk patients (mean/median STS score <4).

View Article and Find Full Text PDF

Background: Due to the presence of complex flow states and significant jet eccentricity in patients with congenital heart disease (CHD), accurate quantification of aortic regurgitation (AR) using standard echocardiographic or conventional cardiac magnetic resonance (CMR) imaging measures remains challenging. Four-dimensional flow (4DF) CMR permits transvalvular flow quantification under non-laminar flow states, although has not been well validated for AR quantification in CHD.

Methods: In 186 patients with moderate or complex CHD, we evaluated the agreement between different methods of AR quantification by 4DF CMR when compared to volumetry.

View Article and Find Full Text PDF

Background: The development of aortic valve regurgitation (AR) negatively affects the survival of patients with continuous-flow left ventricular assist device (LVAD) support. Although several risk factors have been identified, little is known about the effect of preoperative aortic root and valve morphology on the development of de novo AR after LVAD implantation.

Methods: Between April 2018 and September 2023, 87 patients underwent durable LVAD implantation at our department.

View Article and Find Full Text PDF

Background: Sutureless bioprosthetic valves (SBVs) are engineered to enable a less invasive surgical valve replacement procedure in patients at high surgical risk. Valve degeneration is a relatively common occurrence across all types of surgical valves, including SBVs. Valve-in-valve (ViV) procedures are increasingly becoming the preferred treatment for many cases of valve degeneration due to their minimally invasive nature and favourable long-term outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!