A combined MeV-neutron and x-ray source for the National Ignition Facility.

Rev Sci Instrum

Lawrence Livermore National Laboratory, Livermore, California 94550, USA.

Published: October 2022

In support of future radiation-effects testing, a combined environment source has been developed for the National Ignition Facility (NIF), utilizing both NIF's long-pulse beams, and the Advanced Radiographic Capability (ARC) short pulse lasers. First, ARC was used to illuminate a gold foil at high-intensity, generating a significant x-ray signal >1 MeV. This was followed by NIF 10 ns later to implode an exploding pusher target filled with fusionable gas for neutron generation. The neutron and x-ray bursts were incident onto a retrievable, close-standoff diagnostic snout. With separate control over both neutron and x-ray emission, the platform allows for tailored photon and neutron fluences and timing on a recoverable test sample. The platform exceeded its initial fluence goals, demonstrating a neutron fluence of 2.3 ×10 n/cm and an x-ray dose of 7 krad.