Isolation performance metrics for personal sound zone reproduction systems.

JASA Express Lett

3D Audio and Applied Acoustics Laboratory, Princeton University, Princeton, New Jersey 08544, USA.

Published: October 2022

Two isolation performance metrics, inter-zone isolation (IZI) and inter-program isolation (IPI), are introduced for evaluating personal sound zone (PSZ) systems. Compared to the commonly used acoustic contrast metric, IZI and IPI are generalized for multichannel audio and quantify the isolation of sound zones and of audio programs, respectively. The two metrics are shown to be generally non-interchangeable and suitable for different scenarios, such as generating dark zones (IZI) or minimizing audio-on-audio interference (IPI). Furthermore, two examples with free-field simulations are presented and demonstrate the applications of IZI and IPI in evaluating PSZ performance in different rendering modes and PSZ robustness.