Introduction: Collimation of the primary beam is an important factor in radiography to reduce dose and improve image quality. The introduction of larger detector plates in direct digital radiography (DR) allows the exposed area to be calculated by removing cropping applied to the image. The aim of this study was to assess whether the exposed area was larger than a reference standard across five different projections on different body types, with the reference size being the corresponding cassette size used in traditional film/screen or computed radiography (CR).
Method: A retrospective clinical audit of five common musculoskeletal radiographic projections (AP knee, AP shoulder, horizontal beam lateral hip, lateral cervical spine and lateral facial bones), of 359 patients was undertaken. The electronic cropping was removed from projections, and the superior-inferior, antero-posterior and medio-lateral collimation size was measured, depending on the projection. The two measurements were multiplied to give an exposed field of view area. The three measurements were compared with a reference standard, being the size of the corresponding cassette size used in the department on film/screen or computed radiography.
Results: From the five projections, 1071 measurements were analysed. 416 (38.8%) of these measurements were less than or equal to the agreed reference standard. 655 (61.2%) were greater than the agreed reference standard.
Conclusion: The study demonstrates that the majority (61.2%) of the measurements taken were above the reference standard. This results in an increase in radiation dose to patients and detrimental impacts on image quality.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9977647 | PMC |
http://dx.doi.org/10.1002/jmrs.630 | DOI Listing |
Scand J Trauma Resusc Emerg Med
January 2025
Department of Emergency Medicine, Lausanne University Hospital and University of Lausanne, 21 Rue du Bugnon, BH 09, 1011, Lausanne, Switzerland.
Background: The Abbreviated Injury Scale (AIS) and Injury Severity Score (ISS) grade the severity of injuries and are useful for trauma audit and benchmarking. However, AIS coding is complex and requires specifically trained staff. A simple yet reliable scoring system is needed.
View Article and Find Full Text PDFSci Rep
January 2025
Division of Infectious Diseases and Tropical Medicine, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, 110 Intavaroros Rd., Muaeng, Chiang Mai, 50200, Thailand.
Early diagnosis and appropriate treatment are essential for reducing morbidity and mortality in tuberculous meningitis (TBM). This study aimed to evaluate the diagnostic performance of the Xpert MTB/RIF assay for the diagnosis of TBM in patients with subacute lymphocytic meningitis. This cross-sectional study included 65 cerebrospinal fluid (CSF) specimens from patients at Maharaj Nakorn Chiang Mai University Hospital, Thailand, between January 2015 and March 2016.
View Article and Find Full Text PDFSci Rep
January 2025
Support Centre for Advanced Neuroimaging (SCAN), Institute for Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
This study aims to establish an imitation task of multi-finger haptics in the context of regular grasping and regrasping processes during activities of daily living. A video guided the 26 healthy, right-handed volunteers through the three phases of the task: (1) fixation of a hand holding a cuboid, (2) observation of the sensori-motor manipulation, (3) imitation of that motor action. fMRI recorded the task; graph analysis of the acquisitions revealed the associated functional cerebral connectivity patterns.
View Article and Find Full Text PDFAtten Percept Psychophys
January 2025
Department of Developmental and Social Psychology, University of Padova, via Venezia 8, 35131, Padova, Italy.
Numerical and nonnumerical magnitudes can be represented along a hypothetical left-to-right continuum, where smaller quantities are associated with the left side and larger quantities with the right side. However, these representations are flexible, as their intensity and direction can be modulated by various contextual cues and task demands. In four experiments, we investigated the spatial representation of visual speed.
View Article and Find Full Text PDFEur Radiol
January 2025
Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
Objectives: To compare the diagnostic accuracy of ULDCT to CXR for detecting non-traumatic pulmonary diseases at the emergency department (ED) and to study diagnostic confidence levels.
Methods: Secondary analysis of the prospective OPTIMACT trial (2418 ED participants randomly allocated to ULDCT or CXR). Diagnoses at imaging at the ED were compared to the reference diagnosis on day 28.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!