Objectives: To demonstrate the effect of an improved deep learning-based reconstruction (DLR) algorithm on Ultra-High-Resolution Computed Tomography (U-HRCT) scanners.
Methods: Clinical and phantom studies were conducted. Thirty patients who underwent contrast-enhanced CT examination during the follow-up period were enrolled. Images were reconstructed using improved DLR [termed, New DLR, Advanced Intelligent Clear-IQ Engine (AiCE) Body Sharp] and conventional DLR (Conv DLR, AiCE Body) algorithms. Two radiologists assessed the overall image quality using a 5-point scale (5 = excellent; 1 = unacceptable). The noise power spectra (NPSs) were calculated to assess the frequency characteristics of the image noise, and the square root of area under the curve (√AUC NPS) between 0.05 and 0.50 cycle/mm was calculated as an indicator of the image noise. Dunnett's test was used for statistical analysis of the visual evaluation score, with statistical significance set at < 0.05.
Results: The overall image quality of New DLR was better than that of the Conv DLR (4.2 ± 0.4 and 3.3 ± 0.4, respectively; < 0.0001). All New DLR images had an overall image quality score above the average or excellent. The √AUC value of New DLR was lower than that of Conv DLR (13.8 and 14.2, respectively). The median values of reconstruction time required with New DLR and Conv DLR were 5.0 and 7.8 min, respectively.
Conclusions: The new DLR algorithm improved the image quality within a practical reconstruction time.
Advances In Knowledge: The new DLR enables us to choose whether to improve image quality or reduce the dose.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10997025 | PMC |
http://dx.doi.org/10.1259/bjr.20220731 | DOI Listing |
J Osteopath Med
January 2025
Arizona College of Osteopathic Medicine, Midwestern University, Glendale, AZ, USA.
Context: Point-of-care ultrasound (POCUS) has diverse applications across various clinical specialties, serving as an adjunct to clinical findings and as a tool for increasing the quality of patient care. Owing to its multifunctionality, a growing number of medical schools are increasingly incorporating POCUS training into their curriculum, some offering hands-on training during the first 2 years of didactics and others utilizing a longitudinal exposure model integrated into all 4 years of medical school education. Midwestern University Arizona College of Osteopathic Medicine (MWU-AZCOM) adopted a 4-year longitudinal approach to include POCUS education in 2017.
View Article and Find Full Text PDFEClinicalMedicine
December 2024
Nottingham Digestive Diseases Centre (NDDC), Translational Medical Sciences, School of Medicine, University of Nottingham, NG7 2UH, UK.
Background: Despite the availability of various pharmacological and behavioural interventions, alcohol-related mortality is rising. This systematic review aimed to critically evaluate the existing literature on the association between glucagon-like peptide-1 receptor agonists use (GLP-1 RAs) and alcohol consumption.
Methods: Electronic searches were conducted on Ovid Medline, EMBASE, PsycINFO, clintrials.
Whole-body PET imaging is often hindered by respiratory motion during acquisition, causing significant degradation in the quality of reconstructed activity images. An additional challenge in PET/CT imaging arises from the respiratory phase mismatch between CT-based attenuation correction and PET acquisition, leading to attenuation artifacts. To address these issues, we propose two new, purely data-driven methods for the joint estimation of activity, attenuation, and motion in respiratory self-gated TOF PET.
View Article and Find Full Text PDFPurpose: Reliable image quality assessment is crucial for evaluating new motion correction methods for magnetic resonance imaging. In this work, we compare the performance of commonly used reference-based and reference-free image quality metrics on a unique dataset with real motion artifacts. We further analyze the image quality metrics' robustness to typical pre-processing techniques.
View Article and Find Full Text PDFUltrasound localization microscopy (ULM) enables microvascular imaging at spatial resolutions beyond the acoustic diffraction limit, offering significant clinical potentials. However, ULM performance relies heavily on microbubble (MB) signal sparsity, the number of detected MBs, and signal-to-noise ratio (SNR), all of which vary in clinical scenarios involving bolus MB injections. These sources of variations underscore the need to optimize MB dosage, data acquisition timing, and imaging settings in order to standardize and optimize ULM of microvasculature.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!