Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: The diagnostic yield of transbronchial biopsy (TBB) using radial probe endobronchial ultrasound (RP-EBUS) is 71%, which is lower than that of transthoracic needle biopsy. We investigated the performance and safety of sequential transbronchial cryobiopsy (TBC) using a novel 1.1-mm diameter cryoprobe, after conventional TBB using RP-EBUS for the diagnosis of peripheral lung lesions (PLLs).
Materials And Methods: From April 2021 to November 2021, 110 patients who underwent bronchoscopy using RP-EBUS for the diagnosis of PLL ≤ 30 mm were retrospectively included in our study. All records were followed until June 2022.
Results: The overall diagnostic yield of combined TBB and TBC was 79.1%, which was higher than 60.9% of TBB alone (p=0.005). The diagnostic yield of sequential TBC was 65.5%, which increased the overall diagnostic yield by 18.2%. The surface area of tissues by TBC (mean area, 18.5 mm2) was significantly larger than those of TBB by 1.5-mm forceps (3.4 mm2, p < 0.001) and 1.9-mm forceps (3.7 mm2, p=0.011). In the multivariate analysis, PLLs with the longest diameter of ≤ 22 mm were found to be related to additional diagnostic benefits from sequential TBC (odds ratio, 3.51; 95% confidence interval, 1.043 to 11.775; p=0.042). Complications were found in 10.5% of the patients: pneumothorax (1.0%), infection (1.0%), and significant bleeding (8.6%). None of the patients developed any life-threatening complications.
Conclusion: Sequential TBC with a 1.1-mm cryoprobe improved the performance of conventional TBB using RP-EBUS without serious complications.