Objectives: Hand-sewn and stapled intestinal anastomoses are both daily performed routine procedures by surgeons. Yet, differences in micro perfusion of these two surgical techniques and their impact on surgical outcomes are still insufficiently understood. Only recently, hyperspectral imaging (HSI) has been established as a non-invasive, contact-free, real-time assessment tool for tissue oxygenation and micro-perfusion. Hence, objective of this study was HSI assessment of different intestinal anastomotic techniques and analysis of patients' clinical outcome.
Methods: Forty-six consecutive patients with an ileal-ileal anastomoses were included in our study; 21 side-to-side stapled and 25 end-to-end hand-sewn. Based on adsorption and reflectance of the analyzed tissue, chemical color imaging indicates oxygen saturation (StO), tissue perfusion (near-infrared perfusion index [NIR]), organ hemoglobin index (OHI), and tissue water index (TWI).
Results: StO as well as NIR of the region of interest (ROI) was significantly higher in stapled anastomoses as compared to hand-sewn ileal-ileal anastomoses (StO 0.79 (0.74-0.81) vs. 0.66 (0.62-0.70); p<0.001 NIR 0.83 (0.70-0.86) vs. 0.70 (0.63-0.76); p=0.01). In both groups, neither anastomotic leakage nor abdominal septic complications nor patient death did occur.
Conclusions: Intraoperative HSI assessment is able to detect significant differences in tissue oxygenation and NIR of hand-sewn and stapled intestinal anastomoses. Long-term clinical consequences resulting from the reduced tissue oxygenation and tissue perfusion in hand-sewn anastomoses need to be evaluated in larger clinical trials, as patients may benefit from further refined surgical techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9574651 | PMC |
http://dx.doi.org/10.1515/iss-2022-0007 | DOI Listing |
Anal Chem
January 2025
Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, 8092 Zurich, Switzerland.
Droplet-based microfluidics is a powerful tool for high-throughput analysis of liquid samples with significant applications in biomedicine and biochemistry. Nevertheless, extracting content-rich information from single picolitre-sized droplets at high throughputs remains challenging due to the weak signals associated with these small volumes. Overcoming this limitation would be transformative for fields that rely on high-throughput screening, enabling broader multiparametric analysis.
View Article and Find Full Text PDFJ R Soc Interface
January 2025
Faculty of Information Technology, University of Jyväskylä, Jyvaskyla, Finland.
The design of photobioreactors for microalgae cultivation aims to achieve an architecture that allows the most efficient photosynthetic growth. The availability of light at wavelengths that are important for photosynthesis is therefore particularly crucial for reactor design. While testing different reactor types in practice is expensive, simulations could effectively limit the range of material and reactor design options.
View Article and Find Full Text PDFScientific-grade spectrometers with high hyperspectral resolution and high spectral accuracy are desirable in miniaturized optical systems to maintain stable and real-time spectral sampling. Fourier transform spectrometers that utilize high-precision moving mirrors generally struggle to enhance their miniaturization and stable real-time performance. A static infrared spectral measurement method is proposed that uses micro/nano-optical devices as the core of static interference and lightweight imaging.
View Article and Find Full Text PDFIn this paper, we studied the sidewall conditions of 28 × 52 µm InGaN-based blue and green micro-LEDs with different sidewall angles and their effects on external quantum efficiency (EQE). Our findings indicate that steeper sidewall mesas can reduce non-radiative recombination and leakage current, which is beneficial for achieving high internal quantum efficiency (IQE). However, as the sidewall angle increases, the light output from the micro-LED tends to concentrate in the internal region, leading to a decrease in light extraction efficiency (LEE).
View Article and Find Full Text PDFReprod Fertil Dev
January 2025
Fertility & Research Centre, Discipline of Women health, School of Clinical Medicine and the Royal Hospital for Women, University of New South Wales, Sydney, NSW, Australia.
Pre-implantation genetic testing for aneuploidy (PGT-A) via embryo biopsy helps in embryo selection by assessing embryo ploidy. However, clinical practice needs to consider the invasive nature of embryo biopsy, potential mosaicism, and inaccurate representation of the entire embryo. This creates a significant clinical need for improved diagnostic practices that do not harm embryos or raise treatment costs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!