A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure. | LitMetric

Multifocal intraocular lens exchange to monofocal for the management of neuroadaptation failure.

Eye Vis (Lond)

Cornea, Cataract and Refractive Surgery Unit, Vissum (Miranza Group), Alicante, Spain.

Published: November 2022

Background: The aim of this study was to evaluate visual, refractive, quality of vision, visual function and satisfaction of multifocal intraocular lens (MF-IOL) exchange with a monofocal IOL (MNF-IOL) in dissatisfied patients following MF-IOL implantation.

Methods: This was a retrospective case series. Bilateral IOL exchange (MF-IOL to MNF-IOL) was performed in 13 patients (26 eyes) with neuroadaptation failure. Questionnaires including the Quality of Vision (QoV), Visual Function Index (VF-14 and Rasch-revised VF-8R version), and a satisfaction questionnaire were used.

Results: The mean time for IOL exchange was 15 months. The corrected distance visual acuity (CDVA) improved from 20/26 to 20/23 (P = 0.028). The uncorrected near visual acuity (UNVA) worsened after exchange from 20/47 to 20/62 (P = 0.024). QoV scores improved significantly across all three subscales after exchange. Visual function for far distance improved with a change in VF-14 score from 74.2 ± 24.8 to 90.9 ± 9.1 (P = 0.03). The VF-8R score showed worsening although not statistically significant. Near vision spectacle independence was totally or partially lost in all cases. Ten patients (77%) reported they would not repeat the lens exchange. Safety and efficacy indices changed from 1.23 to 0.85, respectively, at three months to 1.24 (P = 0.871) and 0.89 (P = 0.568), respectively, at one year.

Conclusion: IOL exchange (multifocal to monofocal) to solve neuroadaptation failure in this case series resulted in significant improvements in dysphotopsia and improved distance visual function. However, UNVA worsened and patient satisfaction after exchange remained suboptimal with 77% claiming they would not repeat the lens exchange, suggesting the value of near vision spectacle independence for these patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9623973PMC
http://dx.doi.org/10.1186/s40662-022-00311-4DOI Listing

Publication Analysis

Top Keywords

visual function
16
lens exchange
12
neuroadaptation failure
12
iol exchange
12
exchange
10
multifocal intraocular
8
intraocular lens
8
exchange monofocal
8
quality vision
8
case series
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!