Cervical spine movements during laryngoscopy and orotracheal intubation: a systematic review and meta-analysis.

Emerg Med J

Programa de Pós-graduação em Ciências Pneumológicas, Universidade Federal do Rio Grande do Sul, Porto Alegre, Brazil

Published: April 2023

Background: Airway management is challenging in trauma patients because of the fear of worsening cervical spinal cord damage. Video-integrated and optic-integrated devices and intubation laryngeal mask airways have been proposed as alternatives to direct laryngoscopy with the Macintosh laryngoscope (MAC). We performed a meta-analysis to clarify which devices cause less cervical movement during airway management.

Methods: We searched MEDLINE, Cochrane Central, Embase and LILACS from inception to January 2022. We selected randomised controlled trials comparing alternative devices with the MAC for cervical movement from C0 to C5 in adult patients, evaluated by radiological examination. Additionally, cervical spine immobilisation (CSI) techniques were evaluated. We used the Cochrane Risk of Bias Tool to evaluate the risk of bias, and the principles of the Grading of Recommendations, Assessment, Development, and Evaluations system to assess the quality of the body of evidence.

Results: Twenty-one studies (530 patients) were included. Alternative devices caused statistically significantly less cervical movement than MAC during laryngoscopy with mean differences of -3.43 (95% CI -4.93 to -1.92) at C0-C1, -3.19 (-4.04 to -2.35) at C1-C2, -1.35 (-2.19 to -0.51) at C2-C3, and -2.61 (-3.62 to -1.60) at C3-C4; and during intubation: -3.60 (-5.08 to -2.12) at C0-C1, -2.38 (-3.17 to -1.58) at C1-C2, -1.20 (-2.09 to -0.31) at C2-C3. The Airtraq and the Intubation Laryngeal Mask Airway caused statistically significant less movement than MAC restricted to some cervical segments, as well as CSI. Heterogeneity was low to moderate in most results. The quality of the body of evidence was 'low' and 'very low'.

Conclusions: Compared with the MAC, alternative devices caused less movement during laryngoscopy (C0-C4) and intubation (C0-C3). Due to the high risk of bias and the very low grade of evidence of the studies, further research is necessary to clarify the benefit of each device and to determine the efficacy of cervical immobilisation during airway management.

Download full-text PDF

Source
http://dx.doi.org/10.1136/emermed-2021-211160DOI Listing

Publication Analysis

Top Keywords

cervical movement
12
alternative devices
12
risk bias
12
cervical
8
cervical spine
8
airway management
8
intubation laryngeal
8
laryngeal mask
8
quality body
8
devices caused
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!