Optimal lesion formation during catheter-based radiofrequency current (RFC) ablation depends on electro-mechanical tip-tissue coupling measurable contact force (CF) and local impedance (LI) monitoring. We aimed to investigate CF and LI dynamics in patients with previous atrial fibrillation (AF) ablation who frequently present with heterogenous arrhythmia substrate. Data from consecutive patients presenting for repeat AF or atrial tachycardia ablation using a novel open-irrigated single-tip ablation catheter were studied. RFC applications were investigated regarding CF, LI and the maximum LI drop (∆LI) for evaluation of ablation efficacy. ∆LI > 20 Ω was defined as a successful RFC application. A total of 730 RFC applications in 20 patients were analyzed. Baseline CF was not associated with baseline LI (R = 0.06, = 0.17). A mean CF < 8 g during ablation resulted in lower ∆LI (<8 g: 13 Ω vs. ≥ 8 g: 16 Ω, < 0.001). Baseline LI showed a better correlation with ∆LI (R = 0.35, < 0.001) compared to mean CF (R = 0.17, < 0.001). Mean CF correlated better with ∆LI in regions of low (R = 0.31, < 0.001) compared to high (R = 0.21, = 0.02) and intermediate voltage (R = 0.17, = 0.004). Combined CF and baseline LI predicted ∆LI > 20 Ω (area under the receiver operating characteristic curve (AUC) 0.75) better compared to baseline LI (AUC 0.72), mean CF (AUC 0.60), force-time integral (AUC 0.59) and local bipolar voltage (0.55). Combination of CF and LI may aid monitoring real-time catheter-tissue electro-mechanical coupling and lesion formation within heterogenous atrial arrhythmia substrate in patients with repeat AF or atrial tachycardia ablation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9606811PMC
http://dx.doi.org/10.3389/fphys.2022.1001719DOI Listing

Publication Analysis

Top Keywords

repeat atrial
12
contact force
8
force local
8
local impedance
8
atrial fibrillation
8
ablation
8
lesion formation
8
arrhythmia substrate
8
atrial tachycardia
8
tachycardia ablation
8

Similar Publications

Purpose: To optimize the effectiveness and safety of pulmonary vein isolation, pulsed-field ablation (PFA) and high-power short-duration ablation (HPSD) have recently been incorporated into clinical practice. The objective of this study is to conduct a comparative analysis, focusing on the efficacy, safety, and procedural efficiency of PFA and HPSD in the treatment of atrial fibrillation (AF).

Methods: A thorough search was performed across multiple databases to identify trials that compared PFA with HPSD for AF from their inception until July 2024.

View Article and Find Full Text PDF

Objective: Information about congestive heart failure (CHF) treatment in the horse is limited. Torsemide, an oral loop diuretic, is increasingly used in humans, dogs, and cats with CHF. Torsemide is well absorbed and induces diuresis in healthy horses, and its use in a horse with CHF has been reported.

View Article and Find Full Text PDF

There is limited available data regarding the impact of cycle length (CL) prolongation when converting atrial fibrillation (AF) to organized atrial tachycardia (AT) and its effect on clinical outcomes. We retrospectively screened and included a cohort of 132 patients with persistent or long-standing persistent AF who underwent circumferential pulmonary vein isolation (CPVI) and left atrial substrate modification (LASM) between January 2015 and October 2019. In all 132 consecutive patients, persistent AF was successfully converted into organized AT.

View Article and Find Full Text PDF

In this systematic review and meta-analysis, we aimed to validate the predictive role of atrial fibrillation (AF) termination in long-term arrhythmia recurrence. Our search encompassed databases including MEDLINE, EMBASE, PubMed, and the Cochrane Library up to August 1, 2021. Three independent reviewers conducted screening and data extraction.

View Article and Find Full Text PDF

Value of P-wave Parameters in Predicting Outcomes of Repeat Catheter Ablation for Paroxysmal Atrial Fibrillation.

Pacing Clin Electrophysiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.

Background: Pulmonary vein isolation (PVI) has been established as an effective management option for symptomatic paroxysmal atrial fibrillation (PAF). We aimed to explore the role of P-wave parameters in a 12-lead electrocardiogram (ECG) in predicting the success of repeat PAF ablation.

Methods: We enrolled consecutive patients who underwent a second AF ablation procedure for PAF in a UK tertiary center after an index ablation conducted between 2018 and 2019 and a repeat ablation up to 2021.

View Article and Find Full Text PDF