Background: Multiple myeloma (MM) accounts for approximately 10% of hematological malignancies. The monoclonal immunoglobulin G kappa (IgG-κ) daratumumab can bind to CD38 on MM cells and be detected in serum immunofixation (IF), causing pitfalls in M-protein quantification.
Objectives: To determine the efficacy of mitigating the interference of IgG MM treated with daratumumab.
Methods: Levels of Ig, free light chains (FLC) kappa (κ) and lambda (λ), serum protein electrophoresis (SPE)/IF, and Hydrashift 2/4 assays were assessed following manufacturer's instructions in three patients.
Results: Patient 1 was a 70-year-old male diagnosed with IgG-λ MM. The IF distinguished two monoclonal bands (IgG-κ and IgG-λ). With the Hydrashift assay, the daratumumab-anti-daratumumab immune complex shifted the IgG-κ to the α zone, suggesting that the monoclonal IgG-κ band corresponded to daratumumab. Patient 2 was a 63-year-old male with IgG-κ MM who was receiving daratumumab once every other week. SPE/IF assay revealed a faint monoclonal IgG-κ band in the zone. A stronger monoclonal band was observed after administration. The IgG-κ band disappeared on the Hydrashift assay, while the daratumumab-anti-daratumumab complex appeared as a broad smear in the α-region. Patient 3, a 63-year-old male diagnosed with IgG-λMM, was receiving daratumumab once every other month. The IF assay showed two distinct bands (IgG-κ and IgG-λ) post-daratumumab administration. The shift to the α zone of the IgG-κ bands on the Hydrashift assay confirmed that the additional band observed post-infusion was due to the daratumumab.
Conclusions: The Hydrashift assay can help distinguish daratumumab from endogenous M-spike.
Download full-text PDF |
Source |
---|
Cancer Med
August 2024
Department of Hematology Oncology, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Tokyo, Japan.
Background: Immunofixation electrophoresis (IFE) is the standard method for confirming the presence of a monoclonal protein (M-protein) at multiple myeloma (MM) diagnosis. IFE is also essential at assessment of complete response (CR) and stringent CR during treatment. As the CR assessment is influenced by daratumumab and isatuximab, HYDRASHIFT assays were developed.
View Article and Find Full Text PDFClin Chem Lab Med
October 2024
Department of Laboratory Medicine and Genetics, 36626 Samsung Medical Center , Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Objectives: This study evaluates the HYDRASHIFT assay's effectiveness in mitigating daratumumab interference on serum protein tests during multiple myeloma (MM) treatment, aiming to ensure an accurate assessment of treatment response.
Methods: We analyzed 113 serum samples from 68 MM patients undergoing daratumumab treatment, employing both standard IF and the HYDRASHIFT assay. The assay's precision was determined through intra-day and inter-day variability assessments, while its specificity was verified using serum samples devoid of daratumumab.
J Appl Lab Med
July 2024
Sanofi R&D, Chilly-Mazarin, France.
Background: Isatuximab, an IgG-kappa (IgGκ) anti-cluster of differentiation 38 (CD38) monoclonal antibody approved for use in patients with relapsed or refractory multiple myeloma (MM), can potentially interfere with the visualization of endogenous monoclonal protein (M-protein) on standard immunofixation electrophoresis (IFE) and lead to inaccurate classification of a patient's response to therapy. The Hydrashift 2/4 isatuximab IFE assay (Hydrashift isatuximab assay) removes isatuximab interference from IFE. Using samples from patients enrolled in clinical trials of isatuximab-based therapy for MM, we demonstrate how the Hydrashift isatuximab assay improves the ability to detect residual M-protein and offer recommendations for when the assay is most useful.
View Article and Find Full Text PDFClin Biochem
May 2024
Department of Pathology, Duke University Medical Center, Durham, NC, USA; Duke Cancer Institute, Durham, NC, USA. Electronic address:
Objectives: Some therapeutic monoclonal antibodies, like daratumumab and elotuzumab, produce interfering monoclonal bands on serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). Whether other common therapeutic antibodies also produce interference has not been systematically evaluated.
Design And Methods: SPEP/IFE from patients receiving isatuximab (48 patients), belantamab mafodotin (BM; 41), and denosumab (41) were retrospectively reviewed for therapeutic antibody interference.
J Immunol Methods
November 2023
Central Diagnostic Laboratory, section Protein Chemistry, Maastricht University Medical Center+, PO Box 5800, 6202 AZ Maastricht, the Netherlands. Electronic address:
Monoclonal gammopathies are characterized by the presence of monoclonal immunoglobulins, also known as M-proteins. Therapeutic monoclonal antibodies (t-mAbs) can interfere in laboratory assays used to monitor the state of disease, such as serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE). To establish a correct interpretation of IFE, Target protein-Collision Immunofixation Electrophoresis Reflex Assay (T-CIERA) was developed to identify t-mAbs in IFE.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!