Capsulorhexis in white intumescent cataract is often associated with extension leading to radial tears or biradial extension "Argentinian flag sign" and associated complications. We describe a novel technique of managing this situation. Vacuum rhexis is performed with a 24 G bent cannula attached to a 10-ml syringe. The flap is lifted and then caught using 24 G cannula. The suction is manually controlled by the surgeon, and the rhexis is completed using circumferential movement. The chamber stability is well maintained as there is no leakage, and the bent tip gives excellent fulcrum for movement. The advantage of this technique is that a single port is used for maintaining the chamber stability and it needs no special surgical instruments. Vacuum rhexis is a novel surgical technique used for performing successful continuous curvilinear capsulorhexis (CCC) of adequate size in white and intumescent cataracts, with a consistent and predictable outcome.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9907310 | PMC |
http://dx.doi.org/10.4103/ijo.IJO_1631_22 | DOI Listing |
Indian J Ophthalmol
December 2022
Senior Consultant, Grant Medical Foundation, Ruby Hall Clinic , Pune and Bhide Clinic, Pune, Maharashtra, India.
Indian J Ophthalmol
November 2022
Department of Cataract and Refractive Services, SM Eye Hospital, Kangra, Himachal Pradesh, India.
Capsulorhexis in white intumescent cataract is often associated with extension leading to radial tears or biradial extension "Argentinian flag sign" and associated complications. We describe a novel technique of managing this situation. Vacuum rhexis is performed with a 24 G bent cannula attached to a 10-ml syringe.
View Article and Find Full Text PDFOman J Ophthalmol
May 2020
Glaucoma Services, LV Prasad Eye Institute, Mithu Tulsi Chernai Campus, Bhubaneswar, Odisha, India.
Purpose: The purpose is to evaluate the results of the modified direct phaco-chop technique of cataract surgery in eyes with pseudoexfoliation.
Methods: All patients with pseudoexfoliation and visually significant cataract with normal intraocular pressure (IOP) and optic nerve that underwent cataract surgery by the same surgeon using Infiniti, OZil Torsional handpiece (Alcon Labs), were included for this retrospective hospital-based study. Direct vertical or horizontal chop technique was used in all cases with parameters set as required for quadrant removal with high vacuum after the initial cleanup of cortex under the capsulorhexis.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!