A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

National Control Laboratory Assessment of Quality of Rituximab Biosimilars in India. | LitMetric

In past few years many rituximab (RTX) biosimilars have been launched in India. Biosimilars are products that are similar in terms of quality, safety, and efficacy to its innovator product and are expected to offer improved affordability. The less clinical examination is a significant source of reduction in the cost of development of a biosimilar. However, this clinical relief is predicated on the assumption that there is analytical similarity between the biosimilar and the innovator product. Therefore, the role of National Control Laboratory become very important to ensure the quality of these drugs by carrying out analytical characterization at the point of drug product release level as when referred by National Regulatory Authority for quality evaluation. To assess the similarity between innovator and biosimilars, different physicochemical and biological quality attributes were assessed. A multitude of state-of-the-art analysis of  = 3 RTX biosimilars marketed in India revealed that the impurity profiles of these biosimilars measured by charge variant analysis (cation exchange chromatography-high performance liquid chromatography [HPLC], capillary zone electrophoresis, and capillary isoelectric focusing), aggregates profiling (size exclusion chromatography-HPLC), fragments analysis (capillary electrophoresis-sodium dodecyl sulfate) were found to be significantly varying as compared with the innovator product. There were significant variations in acidic variants ( = 0.023) and basic variants ( = 0.0005), isoelectric point value ( < 0.0001), aggregates ( = 0.0231), and fragments ( < 0.0001) of biosimilars were found as that of innovator product. However, these differences were not affecting the biological activity in the cell-based potency analysis by complement-dependent cytotoxicity (CDC) assay ( = 0.1026), antibody-dependent cell-mediated cytotoxicity (ADCC) ( = 0.3736), and binding assay by flow cytometer fluorescence-activated cell sorting ( = 0.4005) of these biosimilars as compared with the innovator product.

Download full-text PDF

Source
http://dx.doi.org/10.1089/mab.2021.0066DOI Listing

Publication Analysis

Top Keywords

innovator product
12
national control
8
control laboratory
8
rtx biosimilars
8
biosimilars
6
quality
5
laboratory assessment
4
assessment quality
4
quality rituximab
4
rituximab biosimilars
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!