A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Left Bundle Branch Pacing Versus Biventricular Pacing for Acute Cardiac Resynchronization in Patients With Heart Failure. | LitMetric

Left Bundle Branch Pacing Versus Biventricular Pacing for Acute Cardiac Resynchronization in Patients With Heart Failure.

Circ Arrhythm Electrophysiol

Department of Cardiology, Zhongshan Hospital of Fudan University, Shanghai Institute of Cardiovascular Diseases, National Clinical Research Center for Interventional Medicine (Y.L., J.W., Z.Y., L.Z., M.L., L.P., X.C., J.C., Y.S., J.G.).

Published: November 2022

Background: Left bundle branch pacing (LBBP) has emerged as an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy. We sought to compare the acute improvement of electrical and mechanical synchrony, and hemodynamics between LBBP and BVP in patients with heart failure and left bundle branch block.

Methods: LBBP and BVP were performed and compared in a crossover fashion in patients with heart failure and left bundle branch block undergoing cardiac resynchronization therapy implantation. Electrical synchrony was assessed by QRS duration and area, mechanical synchrony by the SD of time to peak velocity of 12 left ventricular segments (Ts-SD) and interventricular mechanical delay, and hemodynamics by the maximum rate of left ventricular pressure rise (dP/dt).

Results: Twenty-one patient with heart failure and left bundle branch block (mean age 67±10 years, 48% male, and 90% nonischemic cause) were included. Both LBBP and BVP provided significant improvements in electrical and mechanical synchrony, and hemodynamics compared to the baseline. Compared with BVP, LBBP achieved a larger reduction in QRS duration (-11 ms [95% CI, -17 to -4 ms]; =0.003) and QRS area (-85 µVs [95% CI, -113 to -56 µVs]; <0.001); LBBP achieved a greater decrease in Ts-SD (-14 ms [95% CI, -21 to -7 ms]; =0.001), with no significant difference in interventricular mechanical delay (-2 ms [95% CI, -13 to 8 ms]; =0.63). The increase in dP/dt from LBBP was significantly higher than that from BVP (6% [95% CI, 2%-9%]; =0.002).

Conclusions: LBBP delivers greater acute electrical and mechanical resynchronization and hemodynamic improvement than BVP in predominantly nonischemic heart failure patients with left bundle branch block.

Registration: URL: https://www.

Clinicaltrials: gov; Unique identifier: NCT04505384.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9665950PMC
http://dx.doi.org/10.1161/CIRCEP.122.011181DOI Listing

Publication Analysis

Top Keywords

left bundle
20
bundle branch
20
heart failure
16
cardiac resynchronization
12
patients heart
12
mechanical synchrony
12
lbbp bvp
12
failure left
12
branch pacing
8
biventricular pacing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!