Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
To further reduce the size of a microfluidic detection chip and the sample consumption and to shorten the chip manufacturing cycle, an all-fiber SPR detection multichannel microfluidic chip was proposed and demonstrated in this paper. The microfluidic channel of the proposed chip was provided by the air channel of a double side-hole fiber, the detection unit was fabricated using a dumbbell fiber with a fiber core exposed to air, and the sensing probe was composed and packaged by fiber micro-processing technology. The internal double channels of the fiber constructed from double side-hole and dumbbell fibers can realize dual channel detection based on space division multiplexing. 30 nm silver and 50 nm gold films were respectively coated on the left and right sides of the dumbbell fiber, which can realize the dual channel simultaneous detection based on wavelength division multiplexing. We employed the proposed microfluidic chip to detect immunoglobulin G and dopamine molecules, where the average sensitivity is 0.252 nm (mg mL) and 0.061 nm (μg mL), and the LOD is 0.397 mg mL and 1.639 μg mL, respectively. The microfluidic channel and detection unit of all-fiber multi-channel SPR detection microfluidic chip are provided by a soft and flexible fiber, which is compact in structure, flexible in fabrication and short in manufacturing cycle, making it possible for the microfluidic chip to enter the human body for detection and enabling a new approach for the fabrication of wearable detection microfluidic devices. This provides a new idea for the development of microfluidic chips.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d2lc00681b | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!