Slightly more than 20 years after its first clinical use, highly cross-linked polyethylene (HXLPE) has been widely adopted. Despite initial concerns about oxidation and lack of fatigue resistance, first generation HXLPE, with 15 years of follow-up and widespread use, continues to provide excellent results, even in a young, active population. Remelted HXLPE might have a lower wear rate than annealed HXLPE and will no doubt have a better resistance to oxidation. Second generation materials, consisting of polyethylene (PE) that is sequentially irradiated then annealed and PE that is infused with antioxidants, also have provided encouraging short- and medium-term results. Data from national joint registers confirm data from clinical trials. Even in more challenging cases (dual mobility, hip resurfacing, revision surgery and thin liners), HXLPE has generated promising results. However, failures (rim fractures) have been documented, including for all the latest HXLPE generations. Consequently, certain precautions must be taken during its use and close patient monitoring is necessary.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.otsr.2022.103457 | DOI Listing |
J Orthop Surg Res
January 2025
Department of Orthopaedics, Liaocheng People's Hospital, Liaocheng, Shandong, P.R. China.
Background: Vitamin E-diffused highly cross-linked polyethylene (HXLPE/Vit E) is a relatively advanced material used in total hip arthroplasty (THA) but whether it shows superiority is unclear.
Objective: This meta-analysis was performed to investigate the effect of HXLPE/Vit E liners in THA.
Methods: Medline/PubMed, Embase and Cochrane Library databases were searched to retrieve studies assessing the efficacy of HXLPE/Vit E liners in THA with the design of a randomized, controlled trial.
Hip Int
January 2025
Orthopaedic Clinic Lucerne, Lucerne, Switzerland.
Introduction: The RM Pressfit vitamys is an uncemented, titanium particle-coated, isoelastic monoblock cup made of vitamin E blended highly cross-linked polyethylene. We addressed the following questions: (1) What are the clinical and (2) radiographic outcomes 10 years after implantation? (3) What is the revision rate?
Methods: In this prospective observational study in a tertiary care centre we investigated all consecutive cases of total hip replacement with the RM Pressfit vitamys cup between September 2009 and November 2011. It was implanted in 162 hips, 49.
Bone Joint Res
November 2024
Department of Orthopaedic Surgery, HFR Fribourg - Cantonal Hospital, Fribourg, Switzerland.
Aims: Highly cross-linked polyethylene (HXLPE) greatly reduces wear in total hip arthroplasty, compared to conventional polyethylene (CPE). Cross-linking is commonly achieved by irradiation. This study aimed to compare the degree of cross-linking and in vitro wear rates across a cohort of retrieved and unused polyethylene cups/liners from various brands.
View Article and Find Full Text PDFArthroplast Today
December 2024
Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA.
Background: Modern literature has brought into question if wear of tibial inserts made from conventional or highly crosslinked polyethylene (HXL PE) is still a factor limiting longevity of total knee arthroplasty (TKA) in the mid- to long-term. It is the objective of this study to determine: 1) most common causes of mid- to long-term TKA failure, 2) the prevalence of delamination, and 3) the medial/lateral linear wear rates of conventional and HXL PE tibial inserts retrieved in the mid- to long-term.
Methods: A tibial insert retrieval cohort of 107 inserts (79 conventional, 28 HXL PE) with a minimum time in situ of 6.
J Bone Joint Surg Am
January 2025
Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota.
Background: Second-generation highly cross-linked polyethylene (HXLPE) has revolutionized total hip arthroplasty. However, the long-term risks and benefits of HXLPE in primary total knee arthroplasty (TKA) remain unknown. This randomized clinical trial evaluated implant survivorship, complications, radiographic results, and clinical outcomes of HXLPE and conventional ultra-high molecular weight polyethylene (UHMWPE) inserts in primary TKAs.