We conceptualized and numerically investigated a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor for rapid detection and quantification of novel coronavirus. The plasmonic gold-based optical sensor permits three different ways to quantify the virus concentrations inside patient's body based on different ligand-analyte conjugate pairs. This photonic biosensor demonstrates viable detections of SARS-CoV-2 spike receptor-binding-domain (RBD), mutated viral single-stranded ribonucleic acid (RNA) and human monoclonal antibody immunoglobulin G (IgG). A marquise-shaped core is introduced to facilitate efficient light-tailoring. Analytes are dissolved in sterile phosphate buffered saline (PBS) and surfaced on the plasmonic metal layer for realizing detection. The 1-pyrene butyric acid n-hydroxy-succinimide ester is numerically used to immobilize the analytes on the sensing interface. Using the finite element method (FEM), the proposed sensor is studied critically and optimized for the refractive index (RI) range from 1.3348-1.3576, since the target analytes RIs fluctuate within this range depending on the severity of the viral infection. The polarization-dependent sensor exhibits dominant sensing attributes for x-polarized mode, where it shows the average wavelength sensitivities of 2,009 nm/RIU, 2,745 nm/RIU and 1,984 nm/RIU for analytes: spike RBD, extracted coronavirus RNA and antibody IgG, respectively. The corresponding median amplitude sensitivities are 135 RIU, 196 RIU and 140 RIU, respectively. The maximum sensor resolution and figure of merit are found 2.53 × 10 RIU and 101 RIU, respectively for viral RNA detection. Also, a significant limit of detection (LOD) of 6.42 × 10 RIU/nm is obtained. Considering modern bioassays, the proposed compact photonic sensor will be well-suited for rapid point-of-care COVID testing.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.469937DOI Listing

Publication Analysis

Top Keywords

photonic biosensor
8
detection quantification
8
sensor
6
detection
5
riu
5
plasmonic photonic
4
biosensor situ
4
situ detection
4
quantification sars-cov-2
4
sars-cov-2 particles
4

Similar Publications

Two-dimensional materials with a nanostructure have been introduced as promising candidates for SERS platforms for sensing application. However, the dynamic control and tuning of SERS remains a long-standing problem. Here, we demonstrated active tuning of the enhancement factor of the first- and second-order Raman mode of monolayer (1L) MoS transferred onto a flexible metallic nanotip array.

View Article and Find Full Text PDF

A Highly Stable Electrochemical Sensor Based on a Metal-Organic Framework/Reduced Graphene Oxide Composite for Monitoring the Ammonium in Sweat.

Biosensors (Basel)

December 2024

Guangdong Laboratory of Artificial Intelligence and Digital Economy (SZ), Shenzhen 518107, China.

The demand for non-invasive, real-time health monitoring has driven advancements in wearable sensors for tracking biomarkers in sweat. Ammonium ions (NH) in sweat serve as indicators of metabolic function, muscle fatigue, and kidney health. Although current ion-selective all-solid-state printed sensors based on nanocomposites typically exhibit good sensitivity (~50 mV/log [NH]), low detection limits (LOD ranging from 10 to 10 M), and wide linearity ranges (from 10 to 10 M), few have reported the stability test results necessary for their integration into commercial products for future practical applications.

View Article and Find Full Text PDF

Bright biocompatible fluorescent imaging dyes with red to near-infrared (NIR) emissions are ideal candidates for fluorescence microscopy applications. Pyrene-benzothiazolium hemicyanine dyes are a new class of lysosome-specific probes reported on recently. In this work, we conduct a detailed implementation study for a pyrene-benzothiazolium derivative, BTP, to explore its potential imaging applications in fluorescence microscopy.

View Article and Find Full Text PDF

Rapid and accurate determination of target proteins in cells provide essential diagnostic information for early detection of diseases, evaluation of drug responses, and the study of pathophysiological mechanisms. Traditional Western blotting method has been used for the determination, but it is complex, time-consuming, and semi-quantitative. Here, a tapered seven-core fiber (TSCF) biosensor was designed and fabricated.

View Article and Find Full Text PDF

With advancements in photonic technologies, photonic crystal fibers (PCFs) have become crucial components in developing highly sensitive and efficient biosensors. This paper presents an optimized bowtie-shaped PCF biosensor that leverages surface plasmon resonance (SPR) phenomena for enhanced refractive index (RI) sensing. The proposed design uses an external sensing mechanism to effectively characterize performance across an RI range of 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!