A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

RETRACTED: Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers. | LitMetric

RETRACTED: Transient Response Characteristics Analysis of High-Power Piezoelectric Transducers.

Micromachines (Basel)

Department of Instrument Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240, China.

Published: September 2022

To improve suitability in applications with high dynamic performance requirements, the transient response characteristics of high-power piezoelectric transducers should be studied quantitatively. This paper proposes the vector reduction method to solve the complex transient equations and obtains a transient matching scheme clarifying the mechanism of electrical matching resistance on electromechanical damping. A matching scheme with a combination of full-bridge inverter, transformer and series LC circuit is designed and validated, which can provide suitable electrical damping without causing energy losses. Consequently, the experiment verifies the transient properties of the proposed scheme. For a typical piezoelectric cutting transducer with 100.8 ms response time, our scheme is verified to have high dynamic performance within frequency response time of 5.5 ms and vibration response time of 15.0 ms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9609207PMC
http://dx.doi.org/10.3390/mi13101638DOI Listing

Publication Analysis

Top Keywords

response time
12
transient response
8
response characteristics
8
high-power piezoelectric
8
piezoelectric transducers
8
high dynamic
8
dynamic performance
8
matching scheme
8
response
5
retracted transient
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!