This research has successfully fabricated ion selective electrode (ISE) for Pb2+ using castor oil (Ricinus communis L.)-based polyurethane (PU) membrane with 1,10-phenanthroline as the active agent. The sensitivity of the Pb2+ ISE obtained is 27.25 mV/decade with a linear range of [Pb(NO3)2] of 10−10−10−5 M and a coefficient of determination (R2) of 0.959. The system response reaches stability after 25 s of measurement. The Pb2+ has a detection limit of 10−10 M and gives a stable response at pH 7−8 with a 15-day lifetime. The investigation of the selectivity of the ISE was performed using the mixed solution method with log Kij values of <1. The selectivity order of Pb2+ ISE against the foreign ions is Ag2+ > Ca2+ > K+ > Mg2+ > Cu2+ > Fe3+ > Cr3+> Zn2+ > Cd2+. The Pb2+ ISE shows acceptable reproducibility and repeatability with standard deviation values of 0.065 and 0.0079, respectively. Fourier transform infrared (FT-IR) spectra confirmed that 1,10-phenanthroline was responsible for the formation of the Pb2+ ion entrapment via complexation. Other characterizations (crystallinity, micro-surface morphology, and mechanical strength) suggest the degradation of the membrane structure integrity after the application. The analysis results of Pb levels using the Pb2+ ISE in artificial and wastewater samples were not significantly different from the atomic absorption spectroscopy (AAS) measurement.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9611885 | PMC |
http://dx.doi.org/10.3390/membranes12100987 | DOI Listing |
Biosens Bioelectron
March 2025
College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; State Key Laboratory of Synthetical Automation for Process Industries, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China. Electronic address:
Due to the serious biological toxicity and environmental refractory of heavy metal ions, the detection of heavy metal ions in liquids has attracted great attention. A novel fiber optic surface plasmon resonance (SPR) sensor is presented for detecting lead ions (Pb) with temperature compensation. The sensitivity of SPR channel to Pb is up to -41.
View Article and Find Full Text PDFAnal Chim Acta
August 2024
College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China; National Frontiers Science Center for Industrial Intelligence and Systems Optimization, Northeastern University, Shenyang, 110819, China; Key Laboratory of Data Analytics and Optimization for Smart Industry (Northeastern University), Ministry of Education, China. Electronic address:
Talanta
June 2023
Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao, 266100, China; Sanya Oceanographic Institution, Ocean University of China, Sanya, 572024, China. Electronic address:
Biofouling is a critical issue for ion selective electrodes (ISE) in complex aqueous systems, seriously compromising the analytical performance of the electrodes (i.e., stability, sensitivity, and lifetime).
View Article and Find Full Text PDFMembranes (Basel)
October 2022
Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Syiah Kuala, Banda Aceh 23111, Indonesia.
This research has successfully fabricated ion selective electrode (ISE) for Pb2+ using castor oil (Ricinus communis L.)-based polyurethane (PU) membrane with 1,10-phenanthroline as the active agent. The sensitivity of the Pb2+ ISE obtained is 27.
View Article and Find Full Text PDFAnal Chim Acta
March 2022
Nanyang Environment and Water Research Institute, Residues and Resource Reclamation Center, 1 Cleantech Loop, Cleantech, Singapore, 637141, Singapore; College of Engineering, School of Civil and Environmental Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore, 639798, Singapore. Electronic address:
Metal modified paper-based substrates were utilized for microfluidic paper-based solution sampling coupled with Pb-ion selective electrodes (ISEs) with the aim of controlling the super-Nernstian response which usually occurs when using unmodified paper substrates. Potentiometric responses of Pb-ISEs coupled with gold, platinum and palladium coated paper substrates were investigated. Potentiometric response time was found to be predominantly dependent on the thickness of metallic layer deposited at the paper substrates.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!