Bilateral Knee Joint Cooling on Anaerobic Capacity and Wheel Cadence during Sprint Cycling Intervals.

Healthcare (Basel)

Athletic Training Laboratory, Department of Sports Medicine, Kyung Hee University, Yongin 17104, Korea.

Published: October 2022

We compared the effect of bilateral knee joint cooling with or without a pre-cooling warm-up on sprint cycling performance to a non-cooling control condition. Seventeen healthy young males (25 ± 2 years, 174 ± 6 cm, 70 ± 9 kg) performed three conditions in a counterbalanced order (condition 1: warming + cooling + cycling; condition 2: cooling + cycling; condition 3: cycling). For warming, a single set of cycling intervals (a 10 s sprint with maximal effort followed by a 180 s active recovery; resistive load 4% and 1% body mass for sprint and recovery, respectively) was performed. For cycling, five sets of cycling intervals were performed. For cooling, 20 min of bilateral focal knee joint cooling was applied. Peak and average values of anaerobic capacity and wheel cadence during each set across conditions were statistically compared. There was no condition effect over set (condition × set) in anaerobic capacity (F8,224 < 1.49, p > 0.16) and wheel cadence (F8,224 < 1.48, p > 0.17). Regardless of set (condition effect: F2,224 > 8.64, p < 0.0002), conditions 1 and 2 produced higher values of anaerobic capacity (p ≤ 0.05). Similarly (condition effect: F2,224 > 4.62, p < 0.02), condition 1 showed higher wheel cadence (p < 0.02) than condition 3. A bilateral joint cooling for 20 min with or without pre-cooling warm-up may improve overall sprint cycling capacity during five sets of cycling intervals when compared to the non-cooling condition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9601854PMC
http://dx.doi.org/10.3390/healthcare10101951DOI Listing

Publication Analysis

Top Keywords

joint cooling
16
anaerobic capacity
16
wheel cadence
16
cycling intervals
16
knee joint
12
sprint cycling
12
condition
11
cycling
10
bilateral knee
8
capacity wheel
8

Similar Publications

A lightweight prosthetic hand with 19-DOF dexterity and human-level functions.

Nat Commun

January 2025

Institute of Humanoid Robots, School of Engineering Science, University of Science and Technology of China, Hefei, 230026, China.

A human hand has 23-degree-of-freedom (DOF) dexterity for managing activities of daily living (ADLs). Current prosthetic hands, primarily driven by motors or pneumatic actuators, fall short in replicating human-level functions, primarily due to limited DOF. Here, we develop a lightweight prosthetic hand that possesses biomimetic 19-DOF dexterity by integrating 38 shape-memory alloy (SMA) actuators to precisely control five fingers and the wrist.

View Article and Find Full Text PDF

Background: Reversed shoulder arthroplasty (rTSA) is often used to restore functionality in patients with joint arthropathy and dysfunctional rotator cuff. As rTSA changes the biomechanical properties of the shoulder, an altered movement pattern of arm and scapula is to be expected. Previous studies focused on changes of the scapulohumeral rhythm during functional elevation tasks.

View Article and Find Full Text PDF

Today, composite profiles of constant cross section are widely used in advanced engineering structures. The use of composite profiles in window and door structures can reduce thermal bridging and reduce energy consumption for heating and cooling. This article focuses on the production of new, thermoplastic-based structural pultruded profiles and their application in a PVC (polyvinylchloride) window structure as a reinforcement.

View Article and Find Full Text PDF

High-level multireference configuration interaction plus Davidson correction (MRCI + Q) calculation method was employed to determine the potential energy curves (PECs) of 10 Λ-S states, which come from the first and second dissociation channels of the SbP molecule, as well as 34 Ω states considering the spin-orbit coupling (SOC) effect. By solving the Schrödinger equation for nuclear motion, spectroscopic constants for the ground state XΣ and low-lying excited states were obtained and compared with experimental data. The excellent agreement indicates the reliability of our calculations.

View Article and Find Full Text PDF

A vibrational circular dichroism (VCD) instrument having a thermoelectrically cooled detector (denoted as a TEC unit) was constructed in this study. An electronic device, instead of liquid nitrogen, was employed in the instrument to cool the detector. The feasibility of the system was examined by recording the VCD spectra of liquid pinenes and insect wings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!