Coronary artery disease (CAD) is a global health issue. Lipid peroxidation produces various by-products that associate with CAD, such as 4-hydroxynonenal (HNE) and malondialdehyde (MDA). The autoantibodies against HNE and MDA-modified peptides may be useful in the diagnosis of CAD. This study included 41 healthy controls (HCs) and 159 CAD patients with stenosis rates of <30%, 30−70%, and >70%. The plasma level of autoantibodies against four different unmodified and HNE-modified peptides were measured in this study, including CFAH1211−1230, HPT78−108, IGKC2−19, and THRB328−345. Furthermore, feature ranking, feature selection, and machine learning models have been utilized to exploit the diagnostic performance. Also, we combined autoantibodies against MDA and HNE-modified peptides to improve the models’ performance. The eXtreme Gradient Boosting (XGBoost) model received a sensitivity of 78.6% and a specificity of 90.4%. Our study demonstrated the combination of autoantibodies against oxidative modification may improve the model performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9600024 | PMC |
http://dx.doi.org/10.3390/diagnostics12102269 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!