Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Clenbuterol (CB) is a synthetic -receptor agonist which can be used to improve carcass leanness in swine, but its residues in pork also pose health risks. In this report, surface-enhanced Raman scattering (SERS) technology was used to achieve rapid detection and identification of clenbuterol hydrochloride (CB) residues. First, the effects of several different organic solvents on the extraction efficiency were compared, and it was found that clenbuterol in pork had a better enhancement effect using ethyl acetate as an extraction agent. Then, SERS signals of clenbuterol in different solvents were compared, and it was found that clenbuterol had a better enhancement effect in an aqueous solution. Therefore, water was chosen as the solvent for clenbuterol detection. Next, enhancement effect was compared using different concentration of sodium chloride solution as the aggregating compound. Finally, pork samples with different clenbuterol content (1, 3, 5, 7, 9, and 10 µg/g) were prepared for quantitative analysis. The SERS spectra of samples were collected with 0.5 mol/L of NaCl solution as aggregating compound and gold colloid as an enhanced substrate. Multiple scattering correction (MSC) and automatic Whittaker filter (AWF) were used for preprocessing, and the fluorescence background contained in the original Raman spectra was removed. A unary linear regression model was established between SERS intensity at 1472 cm and clenbuterol content in pork samples. The model had a better linear relationship with a correlation coefficient of 0.99 and a root mean square error of 0.263 µg/g. This method can be used for rapid screening of pork containing clenbuterol in the market.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9599483 | PMC |
http://dx.doi.org/10.3390/bios12100859 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!