Synthetic cathinones comprise a large amount of substances present on the dark market, which creates an undeniably worldwide problem and still is posing a threat. A 22-year-old man was brought to the Emergency Room from a party, where he had ingested orally 20 g of mephedrone. The man exhibited a disorder of consciousness with no logical verbal contact and dilated pupils. Moreover, a metabolic acidosis was present. The patient died after an hour from an admission to the ER. Blood and vitreous humor collected during an autopsy were analyzed with the use of an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-QqQ-MS/MS) with the use of C18 column in multiple reaction monitoring (MRM) mode. Both biological specimens were prepared using liquid-liquid extraction (LLE) with the use of ethyl acetate and 0.5 M ammonium carbonate water solution (pH 9). The limit of quantification (LOQ) of the method was 0.5 ng/ml in both matrices; precision and accuracy values did not exceed ±15%. Recovery of the method was in the range of 86.1%-102.7%. Determined concentrations of 4-CMC were 8542 and 9874 ng/ml in blood and vitreous humor, respectively. Other substances present in both biological materials were: atropine, diazepam, lidocaine, and its metabolite norlidocaine, as well as methcathinone and ethyl alcohol. The concentration presented in here described case is the highest ever reported 4-CMC concentration. Important aspect is also receiving other NPS by recreational users than intended, which lead to accidental poisoning (in presented case user assumed 4-CMC was 4-MMC).

Download full-text PDF

Source
http://dx.doi.org/10.1111/1556-4029.15162DOI Listing

Publication Analysis

Top Keywords

highest reported
8
reported 4-cmc
8
4-cmc concentration
8
blood vitreous
8
vitreous humor
8
fatal case
4
case involving
4
involving highest
4
4-cmc
4
concentration synthetic
4

Similar Publications

Background: Patellar instability is frequently encountered by orthopaedic surgeons. One of the major risk factors of this condition is underlying trochlear dysplasia (TD). Recent trends have indicated the use of multiple procedures to correct patellar instability under these conditions.

View Article and Find Full Text PDF

Introduction: The emergence of high-efficacy disease-modifying therapies (HE DMT) for multiple sclerosis (MS) may pose challenges to the administration and monitoring burden of the therapies. This article presents the results of the Delphi consensus method to generate insights from experts on the administration and monitoring burden of HE DMT in Saudi Arabia with a special focus on cladribine.

Methods: Between January and March 2023, a two-round modified Delphi method was used to establish consensus regarding the administration and monitoring burden of HE DMTs used for MS.

View Article and Find Full Text PDF

Background: To summarize the statistical performance of machine learning in predicting revision, secondary knee injury, or reoperations following anterior cruciate ligament reconstruction (ACLR), and to provide a general overview of the statistical performance of these models.

Methods: Three online databases (PubMed, MEDLINE, EMBASE) were searched from database inception to February 6, 2024, to identify literature on the use of machine learning to predict revision, secondary knee injury (e.g.

View Article and Find Full Text PDF

Objectives: To determine the prevalence of hospital discharge communication problems with older adults, compare them across countries and determine factors associated with those problems.

Design: Secondary analysis of cross-sectional survey data.

Setting: 2021 Commonwealth Fund International Health Policy (IHP) Survey of Older Adults conducted across 11 high-income countries, including Australia, Canada, France, Germany, the Netherlands, New Zealand, Norway, Sweden, Switzerland, the UK and the USA.

View Article and Find Full Text PDF

Statement Of Problem: Different factors affect 3-dimensionally (3D) printed resin products. However, evidence on the effect of the print orientation on resin dental devices is lacking.

Purpose: The purpose of this systematic review and meta-analysis was to assess the impact of print orientation on the properties and accuracy of 3D printed implant surgical guides, occlusal devices, clear orthodontic retainers, and aligners.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!