Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 994
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3134
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
In order to effectively monitor toxic and harmful substances in sewage discharge, a rapid, highly sensitive detection of complex pollutants with similar structures has become an urgent problem to be solved. In this paper, a supramolecular colorimetric array sensor based on charge-transfer complex was constructed, which can quickly detect aniline and phenol pollutants (such as p-phenylenediamine, m-phenylenediamine, o-phenylenediamine, m-aminophenol, hydroquinone, and resorcinol) with similar structures. When six anilines and phenol isomers with similar structures were added to the supramolecular colorimetric array sensor, different color changes were produced under natural light. Linear discriminant analysis (LDA) showed that the supramolecular colorimetric array sensor could recognize and distinguish these isomers, and a mixture with different concentration ratios could be well categorized. The total Euclidean distance (TED) of an array with pollutant concentrations had a good linear correlation, and the detection limit (LOD) was as low as 10-10 mol L. Six anilines and phenol isomers in real samples were identified by supramolecular colorimetric array sensor. H NMR results showed that the formation of charge transfer complexes in Q[8] cavity may be the cause of color change. This work provides a fast and convenient experimental basis for monitoring the complex structure pollutants in sewage discharge.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2022.340504 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!