Purpose: In today's era, fractures of the femur are primarily managed with intramedullary devices. Keeping in mind the anatomical sagittal bow of the femur, intramedullary devices have been devised with an anterior bow, but this varies amongst various manufacturers - leading to complications such as anterior cortex impingement beyond the isthmus and posterior cortical opening at the fracture site. We intend to find the average radius of curvature (ROC) of the anatomical bow of the femur and the variation of the same.

Methods: Radiographic data of 150 normal femur scans done in 81 patients were loaded in the Mimics 21.0 software (Materialise, Leuven, Belgium). A centerline (of the medullary cavity) was created using the software. A best-fit circle was created in the sagittal plane involving a major part of the centerline, and ROC was calculated.

Results: We found the average ROC of our data was 1027.2, with a standard deviation of 241.55. ROC and length of the femur (an indirect measure of height) had a slight positive correlation (r = 0.36; p < 0.05); and a highly positive correlation in the ROC of the left and right femurs of the same individuals (r = 0.605; p < 0.05).

Conclusions: The usual ROC of intramedullary nails is commonly > 1300 mm, much higher than the average ROC we identified in our population. Thus, we conclude that implants with smaller ROC in the range of 1100 mm are needed, leading to better implant placement in the canal and avoiding complications of anterior cortex impingement and preventing fracture gap widening in our setting.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00590-022-03412-xDOI Listing

Publication Analysis

Top Keywords

radius curvature
8
intramedullary devices
8
bow femur
8
femur
6
interest curves
4
curves radius
4
curvature matters
4
matters femur
4
femur fractures
4
fractures based
4

Similar Publications

Improved S-bend optical waveguide loss formula verified by experiments.

Sci Rep

January 2025

Department of Electrical Engineering, Faculty of Science and Technology, University Al Azhar Indonesia, Jakarta, Indonesia.

Curvature of a dielectric waveguide always leads to attenuation of the mode power as it propagates through the curved region. In single mode guides, bending loss becomes significant as the radius of curvature reduces and is strongly dependent on the confinement of the guided mode, so that weakly guiding waveguides can tolerate only large radii of curvature. In this paper we verify our new theoretical version on power loss prediction of S-bend optical waveguides by using analytical theory based on integration of absorption coefficient and compare it to the experimental measurement of such waveguide bends.

View Article and Find Full Text PDF

Background: The increasing prevalence of myopia among Chinese children and adolescents, especially at younger ages, has emerged as a significant concern in recent years. Pre-myopia is a key period for myopia prevention and control in children and adolescents. Previous studies suggested auricular acupressure (AA) therapy might offer a viable approach to prevent and slow down myopia progression.

View Article and Find Full Text PDF

Over the past 30 years, researchers have developed X-ray-focusing telescopes by employing the principle of total reflection in thin metal films. The Wolter-I focusing mirror with variable-curvature surfaces demands high precision. However, there has been limited investigation into the removal mechanisms for variable-curvature X-ray mandrels, which are crucial for achieving the desired surface roughness and form accuracy, especially in reducing mid-spatial frequency (MSF) errors.

View Article and Find Full Text PDF

Compartmental analysis of retinal vascular parameters and thickness in myopic eyes using SS-OCTA.

Front Med (Lausanne)

December 2024

Chongqing Key Laboratory of Prevention and Treatment on Major Blinding Diseases, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Article Synopsis
  • The study examined how myopia affects the thickness and structure of retinal blood vessels using advanced imaging technology in 100 participants.
  • The findings revealed that individuals with high myopia had significantly lower vessel density and thinner retinal layers, particularly noticeable in the superficial and nerve fiber layers.
  • There was a noted correlation between certain ocular parameters, such as axial length to curvature radius ratio, and retinal thickness in non-high myopic eyes, while high myopic eyes showed less correlation in these aspects.
View Article and Find Full Text PDF

Although mixing and matching components is a common, safe, and well-documented practice in hip revision surgery, our extensive search indicates that it has not been previously reported for shoulder arthroplasty. This case report presents the use of mixed implants in shoulder revision surgery to reduce morbidity and address flaws in the initial implant design. We describe a case of a patient with multiple epiphyseal dysplasia who was treated for osteoarthritis in his left shoulder with an anatomic shoulder replacement in 2014.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!