Background: Limited data are available on the incidence of mechanical complications after ultrasound-guided central venous catheterisation. We aimed to determine the incidence of mechanical complications in hospitals where real-time ultrasound guidance is clinical practice for central venous access and to identify variables associated with mechanical complications.
Methods: All central venous catheter insertions in patients ≥16 yr at four emergency care hospitals in Sweden from March 2, 2019 to December 31, 2020 were eligible for inclusion. Every insertion was monitored for complete documentation and occurrence of mechanical complications within 24 h after catheterisation. Multivariable logistic regression analyses were used to determine associations between predefined variables and mechanical complications.
Results: In total, 12 667 catheter insertions in 8586 patients were included. The incidence (95% confidence interval [CI]) of mechanical complications was 7.7% (7.3-8.2%), of which 0.4% (0.3-0.5%) were major complications. The multivariable analyses showed that patient BMI <20 kg m (odds ratio 2.69 [95% CI: 1.17-5.62]), male operator gender (3.33 [1.60-7.38]), limited operator experience (3.11 [1.64-5.77]), and increasing number of skin punctures (2.18 [1.59-2.88]) were associated with major mechanical complication. Subclavian vein catheterisation was associated with pneumothorax (5.91 [2.13-17.26]).
Conclusions: The incidence of major mechanical complications is low in hospitals where real-time ultrasound guidance is the standard of care for central venous access. Several variables independently associated with mechanical complications can be used for risk stratification before catheterisation procedures, which might further reduce complication rates.
Clinical Trial Registration: NCT03782324.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bja.2022.08.036 | DOI Listing |
Clin Appl Thromb Hemost
January 2025
Cardiovascular Research Institute, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, Iran.
Percutaneous valve implantation or surgical replacement with mechanical or biological valves are standard therapies for severe valvular heart diseases. Prosthetic valve thrombosis, though rare, is a serious complication, particularly with mechanical prostheses. This study aimed to investigate the predictive value of platelet volume parameters, including mean platelet volume (MPV), platelet distribution width (PDW), and platelet-large cell ratio (P-LCR), for valvular thrombosis risk in patients undergoing valve replacement therapy.
View Article and Find Full Text PDFCureus
December 2024
Radiology, Saveetha Medical College and Hospital, Saveetha Institute of Medical and Technical Sciences (SIMATS) Saveetha University, Chennai, IND.
Introduction Cosmetic surgery has advanced significantly, with wound closure techniques crucial for determining aesthetic and healing outcomes. Recently, cyanoacrylate glue and subcuticular sutures have gained attention for their unique benefits in cosmetic procedures. Cyanoacrylate glue, a non-invasive tissue adhesive, facilitates faster wound closure with minimal trauma, while subcuticular sutures offer durable, concealed closures, particularly suited for areas under mechanical stress.
View Article and Find Full Text PDFCureus
December 2024
Critical Care Medicine, Star Care Multispeciality Hospital, Kozhikode, IND.
Background: Fluid management is a crucial critical care component, influencing outcomes such as organ function, renal integrity, and survival in critically ill patients. Recent evidence suggests that balanced crystalloids may offer advantages over isotonic saline, particularly in reducing the risk of acute kidney injury (AKI) and other complications. This study aimed to evaluate the impact of balanced crystalloids versus isotonic saline on clinical outcomes in the intensive care unit (ICU), focusing on AKI, renal replacement therapy (RRT), and mortality.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Duke University Medical Center, Durham, North Carolina.
Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
September 2024
Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center and Children's Medical Center, Dallas, Texas.
Background: In small children with left atrioventricular valve dysfunction, valve repair is preferred but some will require valve replacement. No prosthetic valve has growth potential, bioprostheses have poor durability, and mechanical prostheses have high rates of thromboembolic and hemorrhagic complications. We reviewed our experience with a modified bovine jugular vein valve designed for use in the right ventricular outflow tract (Melody valve, Medtronic) and compared this with contemporary mechanical valve replacement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!