Contact allergy to implantable cardiac defibrillators (ICD) is an uncommon and underdiagnosed complication. We report a case of a 20-years-old man patient that was resuscitated from sudden cardiac death. Workup imaging study was unremarkable, but genetic testing identified a mutation in the KCNH2 gene of uncertain significance. The patient underwent a subcutaneous implantable cardiac defibrillator (S-ICD) implantation, with no complications. The patient suffered two hospital re-admissions due to a device-related inflammatory reaction, leading to two device re-implantations. At the first time, it was considered a bacterial infection and the S-ICD was replaced by an endovascular device. At the second time, a tissue-device interaction, with hypersensitivity reaction and device rejection was suspected. The skin patch-tests were inconclusive, but it was decided to implant a custom-made gold-coated endovascular ICD. Indeed, the tendency is an initial misdiagnosis as an infection and a high clinical suspicion is essential to an early diagnosis.