Patients who require dental prosthetic restoration using frame dentures in the front part of the mouth very frequently report that teeth fall out of their dentures. However, the available scientific papers are insufficient to compare the various methods of improving the connection between the denture base and the artificial tooth and choosing the best solution. This paper focuses on providing all parameters, enabling the reproduction of tests, and accounting for all variables. The paper uses an original method of creating grooves, sandpaper, sandblasting, and cutting the acrylate layer with a burr in one and two directions. Developed surfaces were additionally subjected to detailed examination. This study used 180 specimens divided into three groups and subjected to various environments (dry, artificial saliva, and thermocycles). Shearing and tensile strength tests were performed. The best results were obtained with a carbide burr. The increase in connection durability was as follows in the case of the shear test: 116.47% in dry samples, 155.38% in samples soaked in artificial saliva, and 46.59% in samples after thermocycles. The increase in tensile resistance was: 198.96% in a dry environment, 88.10% before being soaked in artificial saliva, and 94.04% after thermocycles.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9590047 | PMC |
http://dx.doi.org/10.3390/jfb13040183 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!