Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Magnetomotive photoacoustic/ultrasound imaging has shown superior specificity in visualizing targeted objects at cellular and molecular levels. By detecting magnet-induced displacements, magnetic-particle-targeted objects can be differentiated from background signals insensitive to the magnetic field. Unfortunately, background physiologic motion interferes during measurement, such as cardiac-induced motion and respiration, greatly reducing the robustness of the technique. In this paper, we propose cyclic magnetomotive imaging with narrowband magnetic excitation. By synchronizing magnetic motion with the excitations, targeted objects moving coherently can be distinguished from background static signals and signals moving incoherently. HeLa cells targeted with magnetic nanoparticle-polymer core-shell particles were used as the targets for an initial test. A linear ultrasound array was interfaced with a commercial scanner to acquire a photoacoustic/ultrasound image sequence (maximum 1000 frames per second) during multi-cycle magnetic excitation (0.5 - 40 Hz frequency range) with an electromagnet. An image mask defined by a threshold on the displacement-coherence map was applied to the original images for background suppression. The results show that contrast was increased by more than 60 dB in an in-vitro experiment with the tagged cells fixed in a polyvinyl-alcohol gel and sandwiched between porcine liver tissues. Using a single sided system, cells injected subcutaneously on the back of a mouse were successfully differentiated from the background, with less than 20 μm coherent magnetic induced displacements isolated from millimetric background breathing motion. These results demonstrate the technique's motion robustness for highly sensitive and specific diagnosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9583729 | PMC |
http://dx.doi.org/10.1117/12.2084906 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!