Step-based metrics provide simple measures of ambulatory activity, yet device software either includes undisclosed proprietary step detection algorithms or simply do not compute step-based metrics. We aimed to develop and validate a simple algorithm to accurately detect steps across various ambulatory and non-ambulatory activities. Seventy-five adults (21-39 years) completed seven simulated activities of daily living (e.g., sitting, vacuuming, folding laundry) and an incremental treadmill protocol from 0.22-2.2ms. Directly observed steps were hand-tallied. Participants wore GENEActiv and ActiGraph accelerometers, one of each on their waist and on their non-dominant wrist. Raw acceleration (g) signals from the anterior-posterior, medial-lateral, vertical, and vector magnitude (VM) directions were assessed separately for each device. Signals were demeaned across all activities and bandpass filtered [0.25, 2.5Hz]. Steps were detected via peak picking, with optimal thresholds (i.e., minimized absolute error from accumulated hand counted) determined by iterating minimum acceleration values to detect steps. Step counts were converted into cadence (steps/minute), and k-fold cross-validation quantified error (root mean squared error [RMSE]). We report optimal thresholds for use of either device on the waist (threshold=0.0267g) and wrist (threshold=0.0359g) using the VM signal. These thresholds yielded low error for the waist (RMSE<173 steps, ≤2.28 steps/minute) and wrist (RMSE<481 steps, ≤6.47 steps/minute) across all activities, and outperformed ActiLife's proprietary algorithm (RMSE=1312 and 2913 steps, 17.29 and 38.06 steps/minute for the waist and wrist, respectively). The thresholds reported herein provide a simple, transparent framework for step detection using accelerometers during treadmill ambulation and activities of daily living for waist- and wrist-worn locations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9586317 | PMC |
http://dx.doi.org/10.1123/jmpb.2021-0011 | DOI Listing |
Plants (Basel)
January 2025
Institute for Bioscience and Biotechnology Research, University of Maryland, Rockville, MD 20850, USA.
Botanical dietary supplements are widely used, but issues of authenticity, consistency, safety, and efficacy that complicate their poorly understood mechanism of action have prompted questions and concerns in the popular and scientific literature. Black cohosh ( L., syn.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Wearable and Gait Assessment Research (WAGAR) Group, Prince of Wales Private Hospital, Randwick, NSW 2031, Australia.
Introduction: Gait analysis is a vital tool in the assessment of human movement and has been widely used in clinical settings to identify potential abnormalities in individuals. However, there is a lack of consensus on the normative values for gait metrics in large populations. The primary objective of this study is to establish a normative database of spatiotemporal gait metrics across various age groups, contributing to a broader understanding of human gait dynamics.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Centro de Química Estrutural, Institute of Molecular Sciences, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa, Portugal.
Healthcare-associated infections (HAI) are a critical public health problem, with 30 to 40% of infections related to the urinary tract system. These urinary tract infections (UTIs) are considered one of the most common microbial infections in hospital settings and everyday community contexts, where approximately 80% are highly correlated with urinary catheter insertion, i.e.
View Article and Find Full Text PDFSensors (Basel)
January 2025
German Center for Vertigo and Balance Disorders (DSGZ), LMU University Hospital, LMU Munich, 81377 Munich, Germany.
Instrumented gait analysis is widely used in clinical settings for the early detection of neurological disorders, monitoring disease progression, and evaluating fall risk. However, the gold-standard marker-based 3D motion analysis is limited by high time and personnel demands. Advances in computer vision now enable markerless whole-body tracking with high accuracy.
View Article and Find Full Text PDFMaterials (Basel)
January 2025
Institute of Chemistry, St. Petersburg State University, 199034 St. Petersburg, Russia.
Deep eutectic solvents (DES) have emerged as versatile, sustainable media for the synthesis of nanomaterials due to their low toxicity, tunability, and biocompatibility. This study develops a one-step method to modify commercially available screen-printed electrodes (SPE) using laser-induced pyrolysis of DES, consisting of choline chloride and tartaric acid with dissolved nickel acetate and dispersed graphene. The electrodes were patterned using a 532 nm continuous-wave laser for the in situ formation of Ni nanoparticles decorated on graphene sheets directly on the SPE surface (Ni-G/SPE).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!