Drug-eluting stents (DES) have revolutionised the treatment of coronary artery disease (CAD) in patients undergoing percutaneous coronary intervention. In recent years, there has been a focus on a new generation of DES, such as biodegradable polymer DES (BP-DES). This novel stent platform was developed with the hope of eliminating the risk of very late stent thrombosis associated with the current gold-standard durable polymer DES (DP-DES). Ultrathin Orsiro BP-DES (Biotronik, Bülach, Switzerland) are based on a cobalt-chromium stent platform that is coated with a bioresorbable polymer coating containing sirolimus. These devices have one of the thinnest struts available in the current market and have the theoretical benefit of reducing a chronic inflammatory response in the vessel wall. In 2019, the United States Food and Drug Administration (FDA) approved the use of Orsiro BP-DES in patients with CAD based on promising results in recent landmark trials, such as BIOFLOW V and BIOSTEMI. The aim of the present review article was to discuss the history of stent technology and the continued opportunities for improvements, focusing on the potential benefits of Orsiro BP-DES.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9559229PMC
http://dx.doi.org/10.17925/HI.2019.13.2.17DOI Listing

Publication Analysis

Top Keywords

orsiro bp-des
12
ultrathin orsiro
8
biodegradable polymer
8
treatment coronary
8
coronary artery
8
artery disease
8
polymer des
8
stent platform
8
stent
5
review ultrathin
4

Similar Publications

Background: The safety and feasibility of using 1-month dual antiplatelet therapy (DAPT) followed by P2Yinhibitor monotherapy for patients after percutaneous coronary intervention (PCI) with thin-strut biodegradable polymer drug-eluting stents (BP-DES) in daily clinical practice remain uncertain.

Methods and results: The REIWA region-wide registry is a prospective study conducted in 1 PCI center and 9 local hospitals in northern Japan. A total of 1,202 patients who successfully underwent final PCI using BP-DES (Synergy: n=400; Ultimaster: n=401; Orsiro: n=401), were enrolled in the registry, and received 1-month DAPT followed by P2Yinhibitor (prasugrel 3.

View Article and Find Full Text PDF

Several studies have demonstrated the safety and feasibility of short (3-6 months) and very short duration (< 2 months) dual antiplatelet therapy (DAPT) in patients with a durable-polymer drug-eluting stent (DP-DES). However, the clinical importance of using very short duration DAPT has yet to be established in patients with a biodegradable polymer drug-eluting stent (BP-DES). The aim of this REIWA registry (multicenter and prospective registry; investigation of clinical outcomes of patients treated with short duration dual antiplatelet therapy after implantation of biodresorbable-polymer drug-eluting stent: a multicenter, prospective registry from Iwate medical university affiliated hospitals) is to determine the safety and feasibility of using 1-month DAPT followed by P2Y12 inhibitor monotherapy in patients after BP-DES implantation.

View Article and Find Full Text PDF

Drug-eluting stents (DES) have revolutionised the treatment of coronary artery disease (CAD) in patients undergoing percutaneous coronary intervention. In recent years, there has been a focus on a new generation of DES, such as biodegradable polymer DES (BP-DES). This novel stent platform was developed with the hope of eliminating the risk of very late stent thrombosis associated with the current gold-standard durable polymer DES (DP-DES).

View Article and Find Full Text PDF

High Bleeding Risk Patients Treated with Very Thin-Strut Biodegradable Polymer or Thin-Strut Durable Polymer Drug-Eluting Stents in the BIO-RESORT Trial.

Cardiovasc Drugs Ther

December 2018

Department of Cardiology, Thoraxcentrum Twente, Medisch Spectrum Twente, Postbus 50.000, 7500, KA, Enschede, the Netherlands.

Purpose: Patients with high bleeding risk (HBR) who undergo percutaneous coronary intervention also have an increased risk of ischemic events and represent an overall high-risk population. The coating of durable polymer drug-eluting stents (DP-DES) may induce inflammation and delay arterial healing, which might be reduced by novel biodegradable polymer DES (BP-DES). We aimed to evaluate the safety and efficacy of treating HBR patients with very thin-strut BP-DES versus thin-strut DP-DES.

View Article and Find Full Text PDF

Aims: We sought to compare vascular healing with bioresorbable everolimus-eluting vascular scaffolds (BVS) and drug-eluting stents with bioabsorbable polymers (BP-DES) at six and 12 months both implanted in the same patients.

Methods And Results: This was a multicentre and prospective study including patients with at least two comparable lesions to treat. In every patient both BVS and BP-DES (SYNERGY, Orsiro or BioMatrix Flex) were implanted by lesion randomisation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!