Background: Bone cement implantation syndrome (BCIS) is a serious and potentially fatal complication especially in patients with osteoporotic femoral neck fracture (OFNF) undergoing cemented hip arthroplasty (CHA). Recent studies showed that the shape-closed femoral stem profile could lead to a significant increase of the intramedullary pressure during cementation and prosthesis insertion. This study aimed to (1) correlate the use of shaped-closed femoral stem and other perioperative risk factors with severe grade of BCIS grade 2 or 3: BCIS gr2/3, and (2) identify the prevalence of BCIS in the elderly patients with OFNF and treated with CHA.

Hypothesis: Large wedge-shaped (or "shape-closed") femoral stem design would significantly associate with BCIS gr2/3 in the elderly patients who sustained OFNF and underwent CHA.

Patients And Methods: A total of 128 OFNF patients, who aged over 75years and underwent CHA were retrospectively reviewed and then allocated into 2 groups: SC Group (use shape-closed femoral stem, n=40) and FC Group (use force-closed femoral stem, n=88). BCIS was grading in all patients according to Donaldson classification. Perioperative data between the patients with BCIS-gr2/3 and those with BCIS grade 0 or 1 (BCIS-gr0/1) were compared. Multiple logistic regression analysis was used to identify predictive factors for BCIS-gr2/3.

Results: The prevalence of overall BCIS and BCIS-gr2/3 was 32.8% (n=42) and 6.2% (n=8), respectively. The total in-hospital and 1-year mortality rates were 2.3% and 4.7%, respectively. The major perioperative complication in patients with BCIS-gr2/3 was significantly higher compared to those in patients with BCIS-gr0/1 (62.5% vs. 10.0%, p=0.001). Multivariate analysis showed that age>90years (OR=9.4, 95% CI: 1.4-62.9, p=0.02), preinjury Parker mobility score<4 (OR=48.8; 95% CI: 2.7-897.2, p=0.008) and shape-closed femoral stem used (OR=19.1; 95% CI: 1.8-204.5, p=0.01) were the significant independent predictors for BCIS-gr2/3 in these patients.

Conclusion: BCIS in OFNF patients undergoing CHA is common and associates with a high major perioperative complication rate. Our initial hypothesis is validated as the patients at risk for BCIS-gr2/3 are those whose CHA procedures use a shape-closed femoral stem design and with extreme age, and having poor preinjury ambulatory status. Therefore, we recommended using cementless stem as the first option in OFNF. However, if CHA is needed, strict guideline for cement insertion should be followed with force-closed stem application to avoid the risk of BCIS-gr2/3.

Level Of Evidence: III; retrospective case-control study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2022.103450DOI Listing

Publication Analysis

Top Keywords

femoral stem
24
shape-closed femoral
12
patients
9
femoral
8
stem design
8
bone cement
8
cement implantation
8
implantation syndrome
8
femoral neck
8
neck fracture
8

Similar Publications

Proximal femoral fractures are particularly common in older adults, and cases requiring conversion to total hip arthroplasty may arise because of treatment failure or osteoarthritis. Fractures around the distal screw removal holes can be problematic. This study aimed to analyze the relationship between stem length and femoral stress distribution to determine the optimal stem length.

View Article and Find Full Text PDF

Large bone defects are still a persistent challenge in orthopedics. The availability limitations and associated complications of autologous and allogeneic bone have prompted an increasing reliance on tissue engineering and regenerative medicine. In this study, we developed an injectable scaffold combining an acellular extracellular periosteal matrix hydrogel with poly(d,l-lactate--glycol-acetate) microspheres loaded with the E7 peptide and miR217 (miR217/E7@MP-GEL).

View Article and Find Full Text PDF

Implant failure of the Compress prosthesis: a case report.

J Med Case Rep

January 2025

Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya University Hospital, 65 Tsurumai, Showa, Nagoya, Aichi, 466-8550, Japan.

Background: The Compress is designed to achieve bone formation and stability by applying pressure at the bone-implant interface, minimizing the likelihood of aseptic loosening, which is a complication of stem implants. Herein, we report two cases of implant failure using the Compress.

Case Presentation: Case 1 describes a 36 year-old Japanese man who underwent extraarticular tumor resection, Compress arthroplasty, and reconstruction with a gastrocnemius flap after preoperative chemotherapy for a secondary malignant giant cell tumor in the right distal femur.

View Article and Find Full Text PDF

Purpose: Proximal femoral fractures are common within the elderly population and are associated with a high risk of mortality and reduced quality of life. Hemiarthroplasty or osteosynthesis (extramedullary or intramedullary) is the primary treatment option for these fractures. However, within this fragile patient population many comorbidities, among others dementia, are seen.

View Article and Find Full Text PDF

Background: Glucocorticoids (GCs) are critical regulatory molecules in the body, commonly utilized in clinical practice for their potent anti-inflammatory and immunosuppressive properties. However, prolonged, high-dose GC therapy is frequently associated with femoral head necrosis, a condition known as glucocorticoid-induced osteonecrosis of the femoral head (GC-ONFH). Emerging evidence suggests that enhanced autophagy may mitigate apoptosis, thereby protecting osteoblasts from GC-induced damage and delaying the progression of ONFH.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?