Objective: Thyroid dysfunction is a common cause of atrial fibrillation (AF). Incidence of AF is high in patients with both expressed and subclinical hyperthyroidism. The aim of our study was to determine the incidence and predictors of new onset atrial fibrillation (NOAF) in euthyroid patients undergoing thyroid surgery.
Subject And Methods: The study included 1,252 euthyroid patients with American Society of Anesthesiologists (ASA) physical status ASA 2 and ASA 3, who were 18 years and older and were in sinus rhythm. Patients without comorbidity and patients with persistent AF were excluded. We investigated the influence of the following preoperative characteristics on the occurrence of NOAF: age, sex, body mass index, ASA score, admission diagnoses, and comorbidity. We noted the influence of difficult intubation of trachea, type and duration of surgery, and time under general anaesthesia. Univariate and multivariate logistic regression were used to determine predictors of occurrence of NOAF.
Results: NOAF was noted in 0.72% of patients. Patients with NOAF were older (63.11 vs. 56.81 years) than patients without NOAF, but this was not statistically significant. Significantly more patients from the NOAF group had preoperative heart rhythm disturbance and a history of angina pectoris, in contrast to patients without registered NOAF (p = 0.001; p = 0.017). Multivariate analysis showed that a history of heart rhythm disturbance was an independent predictor of NOAF.
Conclusions: Incidence of NOAF during thyroid surgery is similar to the other type of surgery, if the values of thyroid hormones are normal.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9841760 | PMC |
http://dx.doi.org/10.1159/000527272 | DOI Listing |
Cardiovasc Eng Technol
January 2025
Institute for Medical Engineering and Science, Massachusetts Institute of Technology, MA, Cambridge, USA.
Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.
View Article and Find Full Text PDFRev Port Cardiol
January 2025
Cardiology Department, Hospital Santa Cruz, Centro Hospitalar Lisboa Ocidental, Lisbon, Portugal.
Introduction And Objectives: Pulmonary vein (PV) isolation is one of the cornerstones of rhythm-control therapy for symptomatic atrial fibrillation (AF) patients. Pulsed field ablation (PFA) is a novel ablation modality that involves the application of electrical pulses causing cellular death, and it has preferential tissue specificity. In this study, we aimed to share a one-year single center experience of AF ablation with PFA.
View Article and Find Full Text PDFAm Heart J
January 2025
Kaufman Center for Heart Failure Treatment and Recovery, Heart Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH. Electronic address:
Background: We aim to validate NT-proBNP nonresponse score (NNRS) previously derived from the PROTECT and BATTLESCARRED studies in comparison with standard health status measures in predicting natriuretic peptide responses in patients with heart failure with reduced ejection fraction.
Methods: Data on the GUIDE-IT trial were used to derive the NNRS based on 4 predictors including baseline NT-proBNP, heart rate, NYHA functional class, and history of atrial fibrillation. The discriminative capacity of the NNRS and health status measures for having NT-proBNP >1,000 pg/mL at 12 months was assessed and compared with baseline or follow-up health status measures including Kansas City Cardiomyopathy Questionnaire Overall Summary Score (KCCQ-OSS), Duke Activity Status Index (DASI), and 6-minute walk distance.
Curr Cardiol Rep
January 2025
Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA.
Purpose Of Review: This review aims to explore how a diagnosis of LMNA-related cardiomyopathy (LMNA-CM) informs clinical management, focusing on the prevention and management of its complications, through practical clinical strategies.
Recent Findings: Longitudinal studies have enhanced our understanding of the natural history of LMNA-CM including its arrhythmic and non-arrhythmic complications. A LMNA specific ventricular arrhythmia risk prediction strategy has been integrated into clinical practice guidelines.
Pacing Clin Electrophysiol
January 2025
Department of Cardiology, Saitama Medical University, International Medical Center, Hidaka, Saitama, Japan.
Background: The IntellaNav MiFi OI catheter (MiFi) is equipped with a sensor for local impedance (LI) monitoring and three mini-electrodes. In this study, we investigated the target LI values for a successful pulmonary vein isolation (PVI) under the pacing and ablation technique using the MiFi catheter.
Methods: Twenty-seven patients underwent PVI using the MiFi catheter under mini electrode pacing from the MiFi catheter.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!