Management of a prosthetic complication on an implant restoration placed when the patient was 10 years old: A case report.

J Prosthodont

Department of Advanced Oral Sciences and Therapeutics, School of Dentistry, University of Maryland, Baltimore, Maryland.

Published: January 2023

The use of dental implants in pediatric patients may create unique complications. A 38-year-old patient presented with a mobile, cement-retained implant crown due to an abutment screw loosening. The maxillary right central incisor implant was placed when the patient was 10 years old. Pus discharge from the peri-implant sulcus was observed. The mucosal margin of the implant was at the level of the mucogingival junction of neighboring teeth. Radiographically, the platform of the implant appeared to be at the level of the apical third of the adjacent roots. After removing the existing implant-retained crown, the inflamed peri-implant tissue covering the implant platform was removed and the stability of the implant was confirmed. A new screw-retained implant crown was made using an angulated screw channel to correct the labiopalatal angulation of the implant and allow for retrievability. Pink porcelain was used to match the mucosal margin of the implant crown to that of the maxillary left central incisor. This case report highlights the risk of implant placement in pediatric patients and agrees with previous reports that implants should be delayed until growth is complete.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.13614DOI Listing

Publication Analysis

Top Keywords

implant crown
12
implant
11
case report
8
pediatric patients
8
central incisor
8
mucosal margin
8
margin implant
8
management prosthetic
4
prosthetic complication
4
complication implant
4

Similar Publications

Background: Tooth agenesis, particularly the absence of upper lateral incisors, presents substantial challenges for clinicians due to the associated bone atrophy, which limits the use of traditional implant solutions. Current options, such as endosseous implants combined with guided bone regeneration (GBR), often fail due to insufficient osseointegration in atrophic bone. This study aims to evaluate the effectiveness of custom-made, additively manufactured subperiosteal implants in addressing these challenges METHODS: This retrospective study assessed 16 custom-made subperiosteal implants used in 12 patients (10 females, 2 males; mean age 25 ± 2.

View Article and Find Full Text PDF

Long-Term Clinical Outcomes and Risk Indicator Analyses of Narrow-Diameter Implants in the Posterior Jaw: A Retrospective Cohort Study of 10 to 27 Years.

Clin Oral Implants Res

January 2025

State Key Laboratory of Oral & Maxillofacial Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan, China.

Objectives: To assess the long-term clinical outcomes and patient satisfaction with narrow-diameter implants (NDIs) in the posterior jaws and to identify the risk indicators for NDI failure.

Materials And Methods: This retrospective study reviewed 479 patients with 666 NDIs (diameter ≤ 3.5 mm) -supported fixed prostheses in posterior jaws, with a minimum 10-year follow-up.

View Article and Find Full Text PDF

Objectives: The aim of this randomised controlled trial was to assess clinical, radiographic and patient reported outcomes of narrow versus standard diameter titanium zirconium (TiZr) implants supporting single crown restorations in posterior sites with limited bone width.

Materials And Methods: Participants requiring replacement of single missing posterior teeth with implant-supported crowns were randomly allocated into 2 treatment groups: narrow (3.3 mm) or standard (4.

View Article and Find Full Text PDF

Effects of thread design on soft and hard tissue healing around implants in lipopolysaccharide-induced peri-implantitis-like lesions in rat maxillae.

J Oral Biosci

January 2025

Department of Applied Prosthodontics, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki 852-8588, Japan. Electronic address:

Objectives: This study investigated the effects of thread design on the soft and hard tissues around implants in rat maxillary peri-implantitis-like lesions.

Methods: Fourteen, 9-week-old, female Wistar rats were used in this study. Two types of grade IV titanium tissue-level implants with a standard V-shape and buttress threads were prepared (control and test implants, respectively).

View Article and Find Full Text PDF

Evaluation of keratinized tissue augmentation using amnion/chorion allograft vs. autogenous connective tissue in implant therapy: a retrospective study.

Clin Oral Investig

January 2025

Department of Surgical Sciences and Integrated Diagnostics, Unit of Implant and Prosthetic Dentistry, University of Genoa, Largo R. Benzi 10 , 16121 , Genova, Italy.

Objectives: Successful implant therapy must also ensure the integration of the soft tissues around the crown/abutment emergence profile. The existing literature does not consistently agree on the necessity of a minimal amount of keratinized tissue (KT), though it appears advantageous for the long-term stability and aesthetics of implants. The purpose of this clinical retrospective study is to compare the effectiveness of amnion/chorion membrane and autogenous subepithelial connective tissue in increasing the keratinized mucosa and maintaining it over a 5-year follow-up.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!