A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Feasibility and safety of three-dimensional electroanatomical cardiac mapping, mapping-guided biopsy and transseptal puncture in dogs. | LitMetric

Three-dimensional electroanatomical mapping (3D EAM) has expanded radiofrequency catheter ablation applications in humans to almost all complex arrhythmias and has drastically reduced fluoroscopy use, yet its potential in dogs is poorly investigated. The objectives of the current study were to assess the feasibility and safety of 3D EAM of all four heart chambers, 3D EAM-guided biopsies and transseptal puncture in dogs. Eight healthy purpose-bred Beagle dogs. Electroanatomical mapping was performed under general anaesthesia during sinus rhythm using a 22-electrode mapping catheter. Left heart catheterisation was achieved by either retrograde transaortic access (n = 4) or transseptal puncture (n = 4). Successful 3D EAM of the right atrium and ventricle was achieved in all dogs at a median time of 33 (13-40) min and 17 (3-52) min, respectively. Left atrial and ventricular 3D EAM was successful in six and seven dogs, at a median time of 17 (4-27) min and 8 min (4-19 min), respectively. Complications requiring intervention occurred in one dog only and were a transient third degree atrioventricular block and pericardial effusion following transseptal puncture, which was treated by pericardiocentesis. All dogs recovered uneventfully. Fluoroscopy time was limited to a median of 7 min (0-45 min) and almost exclusively associated with transseptal puncture. Three-dimensional EAM of all cardiac chambers, including mapping-guided biopsy and transseptal puncture is feasible in small dogs. Complications are similar to those reported in human patients. This suggests a potential added value of 3D EAM to conventional electrophysiology in dogs with arrhythmias.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvc.2022.09.002DOI Listing

Publication Analysis

Top Keywords

transseptal puncture
24
dogs
9
feasibility safety
8
three-dimensional electroanatomical
8
mapping-guided biopsy
8
biopsy transseptal
8
puncture dogs
8
electroanatomical mapping
8
dogs median
8
median time
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!