Fluoranthene (FLU) has gained much attention in recent years because of its continuous discharge in natural waters and toxicity to aquatic ecosystems. However, it is difficult to control and manage FLU pollution because of the lack of a rational and scientific water quality criteria (WQC) of FLU. To solve these data gaps, the US EPA established an interspecies correlation estimation (ICE) model, which can be utilized to develop the SSD and HC (hazardous concentration, 5th percentile). Moreover, an improved model was developed using a combination of North American ICE models supplemented with China-specific species. In this study, to verify the applicability of the two ICE models, measured acute toxicity data for FLU were obtained from 9 acute toxicity tests using indigenous Chinese aquatic species from different taxonomic levels. Original and improved ICE-based SSD curves, which were generated using 3 surrogate species (Daphnia magna, Oncorhynchus mykiss, and Lepomis macrochirus), were compared with SSD curves based on measured data. The results showed that HC was 1.838, 1.062, and 0.570 mg/L for the original ICE, improved ICE, and measured data, respectively. The improved ICE-based HC value for FLU was within twofold of the HC value based on measure data, while the original ICE-based HC value was threefold higher than the HC value based on measure data. This indicated that the improved ICE had better predictability in extrapolating data with acceptable deviation than the original ICE. Furthermore, their differences between HC derived from two SSD curves were not significant. Generally, the improved ICE model was verified as a valid approach for generating SSDs with limited toxicity data and for deriving WQC for FLU.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11356-022-23612-6 | DOI Listing |
Ther Adv Infect Dis
January 2025
Clinica di Malattie Infettive, Fondazione IRCCS Policlinico San Matteo, Pavia 27100, Italy.
Background: Daptomycin pharmacokinetics and pharmacodynamics data relative to higher doses in patients are necessary for clinical practice.
Objectives: A monocentric, prospective study that enrolled patients with a diagnosis of spp. infective endocarditis treated with daptomycin according to clinical practice, to evaluate the pharmacokinetics/pharmacodynamics of different daptomycin daily doses (group A: 8-10 and group B: 11-12 mg/kg).
Sci Total Environ
December 2024
Department of Biology, University of Naples Federico II, Via Vicinale Cupa Cintia 26, 80126 Naples, Italy. Electronic address:
Rare earth elements (REEs) encompass 15 lanthanides and play a crucial role in modern technology. Despite their essential uses, REEs are emerging environmental contaminants due to their growing presence in industrial, agricultural, and medical applications. For the first time, the species sensitivity distribution (SSD) approach was applied to REEs considering 58 papers including toxicity about Ce, Dy, Er, Gd, La, Lu, Nd, Pr, Sm, and Y.
View Article and Find Full Text PDFWater Res
December 2024
Guangdong Provincial Key Laboratory of Soil and Groundwater Pollution Control, School of Environmental Science and Engineering, Southern University of Science and Technology, Shenzhen 518055, PR China. Electronic address:
Microplastics have been proven to impact a broad range of marine species significantly. This study investigated the vertical distribution characteristics of microplastics (MPs) to verify their potential toxicity, distribution patterns, and affecting probability on organisms offshore of the East China Sea (ECS), China. Significant variations in MP characteristics across stratified water layers were identified and corroborated through artificial neural network (ANN) analysis.
View Article and Find Full Text PDFJ Appl Clin Med Phys
November 2024
Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut, USA.
Purpose: In vivo dosimetry is a common requirement to validate dose accuracy/uniformity in total body irradiation (TBI). Several detectors can be used for in vivo dosimetry, including thermoluminescent dosimeters (TLDs), diodes, ion chambers, optically stimulated luminescent dosimeters (OSLDs), and film. TLDs are well established for use in vivo but required expertise and clinical system availability may make them impractical for multifractionated TBI.
View Article and Find Full Text PDFBMJ Open
November 2024
Department of Psychosomatic Medicine and Psychotherapy, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!