Diffusion-weighted magnetic resonance imaging is prone to have susceptibility artifacts in an inhomogeneous magnetic field. We compared distortion and artifacts among three diffusion acquisition techniques (single-shot echo-planar imaging [SS-EPI DWI], readout-segmented EPI [RESOLVE DWI], and 2D turbo gradient- and spin-echo diffusion-weighted imaging with non-Cartesian BLADE trajectory [TGSE-BLADE DWI]) in healthy volunteers and in patients with a cerebral aneurysm clip. Seventeen healthy volunteers and 20 patients who had undergone surgical cerebral aneurysm clipping were prospectively enrolled. SS-EPI DWI, RESOLVE DWI, and TGSE-BLADE DWI of the brain were performed using 3 T scanners. Distortion was the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI near air-bone interfaces in healthy volunteers (P < 0.001). Length of clip-induced artifact and distortion near the metal clip were the least in TGSE-BLADE DWI, and lower in RESOLVE DWI than SS-EPI DWI (P < 0.01). Image quality scores for geometric distortion, susceptibility artifacts, and overall image quality in both healthy volunteers and patients were the best in TGSE-BLADE DWI, and better in RESOLVE DWI than SS-EPI DWI (P < 0.001). Among the three DWI sequences, image quality was the best in TGSE-BLADE DWI in terms of distortion and artifacts, in both healthy volunteers and patients with an aneurysm clip.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9586944PMC
http://dx.doi.org/10.1038/s41598-022-22760-6DOI Listing

Publication Analysis

Top Keywords

healthy volunteers
16
tgse-blade dwi
12
resolve dwi
12
ss-epi dwi
12
volunteers patients
12
cerebral aneurysm
12
dwi
9
dwi resolve
8
dwi ss-epi
8
patients cerebral
8

Similar Publications

Real-Time Tractography-Assisted Neuronavigation for Transcranial Magnetic Stimulation.

Hum Brain Mapp

January 2025

Department of Neuroscience and Biomedical Engineering, School of Science, Aalto University, Espoo, Finland.

State-of-the-art navigated transcranial magnetic stimulation (nTMS) systems can display the TMS coil position relative to the structural magnetic resonance image (MRI) of the subject's brain and calculate the induced electric field. However, the local effect of TMS propagates via the white-matter network to different areas of the brain, and currently there is no commercial or research neuronavigation system that can highlight in real time the brain's structural connections during TMS. This lack of real-time visualization may overlook critical inter-individual differences in brain connectivity and does not provide the opportunity to target brain networks.

View Article and Find Full Text PDF

Purpose: This study aimed to explore the potential application of NAO in guiding patients through rehabilitative exercises using external audiovisual stimuli, focusing on temporospatial control in terms of range of motion (ROM), execution time and movement smoothness.

Methods: This is a preliminary analysis involving ten healthy volunteers and two patients with shoulder musculoskeletal disorders. The protocol was developed in two phases (III and IV) with different ROM limits and including flexion-extension (FE), external-rotation (ER) and internal-rotation (IR) exercises, performed at two speeds and both with and without NAO assistance.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the diagnostic performance of ESAT6-CFP10 (EC) skin test in healthy population and determine the factors influencing the booster effect.

Methods: We conducted a randomized, double-blind, parallel controlled trial in healthy population. The experiment was divided into two stages.

View Article and Find Full Text PDF

Respiratory syncytial virus (RSV) is the leading cause of lower respiratory tract infection (LRTI) in infants worldwide. Nirsevimab, an extended half-life monoclonal antibody against RSV, is approved in China for the prevention of RSV lower respiratory tract disease in infants; however, global nirsevimab trials did not enroll Chinese infants. To inform the investigation of nirsevimab for the prevention of RSV LRTI in Chinese infants, this Phase I, randomized, placebo-controlled trial evaluated the pharmacokinetics (PK) and safety of nirsevimab in healthy Chinese adults.

View Article and Find Full Text PDF

Harmonic-to-noise ratio as speech biomarker for fatigue: K-nearest neighbour machine learning algorithm.

Med J Armed Forces India

December 2024

Associate Professor, Dayanand Sagar Univerity, Bengaluru, India.

Background: Vital information about a person's physical and emotional health can be perceived in their voice. After sleep loss, altered voice quality is noticed. The circadian rhythm controls the sleep cycle, and when it is askew, it results in fatigue, which is manifested in speech.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!