Introduction: Hip arthroplasty is the treatment of choice for displaced femoral neck fractures among the older population. The hip prosthesis dislocation is one of the most pointed potential complications after hip arthroplasty, but there is a lack of updated information on the effect of dislocation on the survival of older hip fracture patients so treated by hip hemiarthroplasty. We aim to evaluate the standalone effect of hip prosthesis dislocation after hip fracture hemiarthroplasty on patients' survival outcomes.
Materials And Methods: We conducted a retrospective multicenter study, including 6631 femoral neck fracture patients over 65 surgically treated by hemiarthroplasty. We made follow-up cut-offs 30-days, 6 weeks, 90-days, and one year after hospital discharge determining hip dislocation rate and patients' survival.
Results: The women population represented 78.7%, and the mean age of the population was 85.2 ± 6.7 years. Hip prosthesis dislocation incidence was 1.9% in the first 90-days after discharge, representing 91.54% of primary dislocations yearly noted. We reported statistically significant increased mortality rates of patients presenting at least one hip prosthesis dislocation event (from 16.0% to 24.6% at 90-day after discharge, and 29.5% to 44.7% at one year), and also significantly decreasing patient survival function at 90-day (P = .016) and one-year follow-up (P < .001). The recurrent dislocation events (26.15%) showed even higher mortality rates (up to 60.6%, p < .001). The multivariate Cox regression model determined that prosthesis dislocation was the only significant variable (P = .035) affecting patient survival, increasing the risk of dying before one year of follow-up by 2.7 times.
Discussion: Our study stands for the standalone hip prosthesis dislocation entailing a higher risk of death after hip fracture hemiarthroplasty in the older population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.recot.2022.10.013 | DOI Listing |
Large-diameter heads (LDHs) in total hip arthroplasty (THA) enhance range of motion but require thinner liners. Monoblock acetabular components with ceramic liners could reduce liner fracture risks during modular acetabular component assembly. This study aims to confirm the safety and clinical performance of the monoblock Maxera Cup in THA.
View Article and Find Full Text PDFObjective: To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
Methods: Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Sports Medicine, the First Affiliated Hospital of Kunming Medical University, Kunming Yunnan, 650032, P. R. China.
Objective: To investigate the effectiveness of modified single patellar tunnel medial patella femoral ligament (MPFL) reconstruction in the treatment of recurrent patellar dislocation.
Methods: Between January 2023 and June 2023, a total of 61 patients with recurrent patellar dislocation who underwent MPFL reconstruction with autologous semitendinosus were enrolled and divided into 2 groups using random number table method. In the patellar anchor group, 31 patients were treated with MPFL reconstruction with double medial patellar anchors, and 30 patients in the patellar tunnel group were treated with MPFL reconstruction with single patellar tunnel.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Artificial Joint Revision, Luoyang Orthopedic-Traumatological Hospital of Henan Province (Henan Provincial Orthopedic Hospital), Zhengzhou Henan, 450003, P. R. China.
Objective: To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects.
Methods: A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
January 2025
Department of Orthopedics, 920th Hospital of the Joint Logistics Support Force of Chinese PLA, Kunming Yunnan, 650000, P. R. China.
Objective: To evaluate the early effectiveness of navigation-free robot-assisted total knee arthroplasty (TKA) compared to traditional TKA in the treatment of knee osteoarthritis combined with extra-articular deformities.
Methods: The clinical data of 30 patients with knee osteoarthritis combined with extra-articular deformities who met the selection criteria between June 2019 and January 2024 were retrospectively analyzed. Fifteen patients underwent CORI navigation-free robot-assisted TKA and intra-articular osteotomy (robot group) and 15 patients underwent traditional TKA and intra-articular osteotomy (traditional group).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!