A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dual Application of Patient-Specific Occlusion-Based Positioning Guide and Fibular Cutting Guide for Accurate Reconstruction of Segmental Mandibular Defect. | LitMetric

Dual Application of Patient-Specific Occlusion-Based Positioning Guide and Fibular Cutting Guide for Accurate Reconstruction of Segmental Mandibular Defect.

J Craniofac Surg

Department of Plastic and Reconstructive Surgery, Seoul Asan Medical Center, College of Medicine, University of Ulsan, Seoul, Korea.

Published: July 2023

In this study, the authors introduced a dual application of patient-specific occlusion-based positioning guide and fibular cutting guide to obtain ideal occlusal relationship and mandibular contour in patients undergoing mandibular reconstruction. A retrospective review was performed in 21 patients who underwent mandibular reconstruction with a fibular osteocutaneous free flap. Using computed tomography and intraoral scanning data, fibular cutting guide and occlusion-based positioning guide were simulated in a modeling software and 3-dimensionally printed. Both guides were applied in 9 patients, defined as dual guide group, while the fibular cutting guide was solely used in the remaining patients, defined as single guide group. Functional outcomes including occlusion status, trismus, presence of osseointegrated implant were assessed at 1-year postoperative period. To evaluate the accuracy of the reconstruction, the discrepancy between the planned simulation and actual surgical result was quantified by measuring mandibular deviation angle and volume conformity. Regarding the functional outcomes, all patients in dual guide group showed satisfactory occlusion and intact oral capacity at postoperative 1-year assessment, while 3 patients in single guide group had prolonged malocclusion. The dual guide group showed significantly decreased deviation angle in coronal (right side, 2.93°±1.98° vs. 7.02°±2.81°, P =0.003) and axial plane (right side, 3.20°±2.04° vs. 7.63°±3.40°, P =0.006). The mean volume conformity between the simulation and actual fibular object was significantly higher in the dual guide group (75.27%±6.12% vs. 59.06%±8.57%, P =0.001). In conclusion, the use of occlusion-based positioning guide combined with the fibular cutting guide can enhance the accuracy of mandible reconstruction and functional outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000009073DOI Listing

Publication Analysis

Top Keywords

guide group
24
fibular cutting
20
cutting guide
20
occlusion-based positioning
16
positioning guide
16
dual guide
16
guide
15
functional outcomes
12
dual application
8
application patient-specific
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!