AI Article Synopsis

  • Developed an automatic thalamus segmentation method using a 3D convolutional neural network (CNN) on diverse T1-weighted MRI data, eliminating the need for standard scanner protocols.
  • Achieved high accuracy in segmenting the thalamus, comparable to existing methods, with better stability in volume estimates across different MRI scanners.
  • The 3D CNN demonstrated superior sensitivity in detecting thalamus atrophy in multiple sclerosis patients, indicating potential for improved clinical diagnosis and monitoring.

Article Abstract

Objectives: To develop an automatic method for accurate and robust thalamus segmentation in T1w-MRI for widespread clinical use without the need for strict harmonization of acquisition protocols and/or scanner-specific normal databases.

Methods: A three-dimensional convolutional neural network (3D-CNN) was trained on 1975 T1w volumes from 170 MRI scanners using thalamus masks generated with FSL-FIRST as ground truth. Accuracy was evaluated with 18 manually labeled expert masks. Intra- and inter-scanner test-retest stability were assessed with 477 T1w volumes of a single healthy subject scanned on 123 MRI scanners. The sensitivity of 3D-CNN-based volume estimates for the detection of thalamus atrophy was tested with 127 multiple sclerosis (MS) patients and a normal database comprising 4872 T1w volumes from 160 scanners. The 3D-CNN was compared with a publicly available 2D-CNN (FastSurfer) and FSL.

Results: The Dice similarity coefficient of the automatic thalamus segmentation with manual expert delineation was similar for all tested methods (3D-CNN and FastSurfer 0.86 ± 0.02, FSL 0.87 ± 0.02). The standard deviation of the single healthy subject's thalamus volume estimates was lowest with 3D-CNN for repeat scans on the same MRI scanner (0.08 mL, FastSurfer 0.09 mL, FSL 0.15 mL) and for repeat scans on different scanners (0.28 mL, FastSurfer 0.62 mL, FSL 0.63 mL). The proportion of MS patients with significantly reduced thalamus volume was highest for 3D-CNN (24%, FastSurfer 16%, FSL 11%).

Conclusion: The novel 3D-CNN allows accurate thalamus segmentation, similar to state-of-the-art methods, with considerably improved robustness with respect to scanner-related variability of image characteristics. This might result in higher sensitivity for the detection of disease-related thalamus atrophy.

Key Points: • A three-dimensional convolutional neural network was trained for automatic segmentation of the thalamus with a heterogeneous sample of T1w-MRI from 1975 patients scanned on 170 different scanners. • The network provided high accuracy for thalamus segmentation with manual segmentation by experts as ground truth. • Inter-scanner variability of thalamus volume estimates across different MRI scanners was reduced by more than 50%, resulting in increased sensitivity for the detection of thalamus atrophy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9935653PMC
http://dx.doi.org/10.1007/s00330-022-09170-yDOI Listing

Publication Analysis

Top Keywords

thalamus volume
16
thalamus segmentation
16
thalamus
14
convolutional neural
12
neural network
12
sensitivity detection
12
t1w volumes
12
mri scanners
12
volume estimates
12
automatic segmentation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!