Background And Aims: The stress response to pneumoperitoneum can be deleterious due to its effects on haemodynamics, thereby increasing the morbidity. We intended to compare different doses of nitroglycerine nasal spray to obtund these responses and to look for any side effects.

Methods: After ethical committee clearance and clinical trials registration, 70 patients scheduled for laparoscopic cholecystectomy were recruited. Random allocation was done into two groups by a computer generated randomisation table. Group N4 (n = 35) received 400 μg nitroglycerine and group N8 (n = 35) received 800 μg nitroglycerine with an intranasal spray 2 min prior to pneumoperitoneum. All the haemodynamic parameters were monitored at regular intervals.

Results: The heart rate was comparable between the groups except at 6 and 10 min of pneumoperitoneum but showed significant increase from baseline within the groups. Mean arterial pressure (MAP) was statistically significant between the groups, being higher in group N4. Within group N4, MAP was significantly low only at 2 min, 4 min of pneumoperitoneum (101.69 ± 12.34 at baseline versus 93.31 ± 8.07 at 2 min and 97.54 ± 9.07 mm Hg at 4 min) and increased significantly at 30 min of pneumoperitoneum (101.69 ± 12.34 at baseline versus 105.66 ± 12.35 mm Hg) and hence, MAP was observed to be around baseline throughout the rest of intraoperative period. Within group N8, there was a significant decrease in mean, systolic and diastolic blood pressure from baseline at most of the time intervals.

Conclusion: 800 μg of intranasal nitroglycerine effectively obtunds the hypertensive response associated with pneumoperitoneum as compared to 400 μg without significant side effects.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9575924PMC
http://dx.doi.org/10.4103/ija.ija_952_21DOI Listing

Publication Analysis

Top Keywords

min pneumoperitoneum
12
intranasal nitroglycerine
8
stress response
8
response pneumoperitoneum
8
group received
8
400 μg
8
μg nitroglycerine
8
800 μg
8
pneumoperitoneum 10169
8
10169 1234
8

Similar Publications

Background: Little is known about the effect of electroacupuncture (EA) on cerebral blood flow. We investigated this question in patients undergoing laparoscopic cholecystectomy, hypothesizing that EA would increase cerebral blood flow during surgery.

Methods: Eighty-two patients undergoing laparoscopic cholecystectomy were randomly divided into receiving electroacupuncture and intravenous anesthesia (EA+IA) and receving intravenous anesthesia alone (IA).

View Article and Find Full Text PDF

Background: Pediatric inguinal hernia is a common surgical condition among children. In this study, we present the application of a self-designed laparoscopic auxiliary needle device (China Patent Number: ZL 201320479515.5) and evaluate its effectiveness in laparoscopic percutaneous extraperitoneal closure in pediatric patients.

View Article and Find Full Text PDF

Introduction: Inguinal hernia surgery, a common procedure worldwide, continues to develop to achieve minimal access and tension-free repairs. However, a universally accepted technique has yet to be developed. Our study introduces a new approach, a modified tumescent transabdominal pre-peritoneal (TAPP), to a low-cost setting.

View Article and Find Full Text PDF

Changes of endotracheal tube cuff pressure and its indicators in laparoscopic resection of colorectal neoplasms: an observational prospective clinical trial.

BMC Anesthesiol

November 2024

Department of Anesthesiology, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, Jiangsu Province, 210008, P. R. China.

Article Synopsis
  • Laparoscopic surgery for colorectal neoplasms can raise airway pressure, especially if the cuff pressure of the endotracheal tube isn't monitored, leading to potential complications.
  • This study involved 122 patients and aimed to identify factors predicting out-of-range tracheal tube cuff pressure during surgery, with waist-to-hip ratio emerging as the best predictor.
  • Results indicated that continuous monitoring of cuff pressure is essential for patients with normal BMI, and adjustments may be necessary to maintain safe pressure levels during the procedure.
View Article and Find Full Text PDF
Article Synopsis
  • This study examined the impact of lung protective ventilation (LPV) versus conventional ventilation on reducing pulmonary atelectasis and enhancing oxygen levels in infants undergoing laparoscopic surgery.
  • Eighty infants aged 1-6 months were divided into two groups, with LPV using lower tidal volumes and specific strategies for lung recruitment, while the control group used higher tidal volumes and no positive end-expiratory pressure (PEEP).
  • Results indicated that LPV significantly lowered the incidence of atelectasis and improved oxygenation during surgery, but these improvements were not sustained by the time the infants were discharged from post-anesthesia care.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!