The aim of this study was to evaluate patient satisfaction and usability scores of different tape treatments and examine the scores in relation to the mechanical characteristics of the tape formulation. A questionnaire for the assessment of comfort level and satisfaction with two brand-name (Naboal, Voltaren) and four generic tapes (Yutoku, Teikoku, Rakool, Towa) containing sodium diclofenac was developed and then applied to 12 healthy volunteers. Results showed that Voltaren was difficult to apply to the skin and easier to peel off the skin than Naboal (p < 0.01). Moreover, Rakool was easier to peel than Naboal (p < 0.05). The mechanically measured peeling force was associated with pain during peeling off (r = -0.65), and the measured value of bending rigidity was associated with ease of peeling off (r = -0.97). The knowledge obtained regarding the influence of pharmaceutical properties on the degree of satisfaction with and usability of different tape formulations may be useful for supporting the selection of generic tapes tailored to individual needs or pharmacist preferences, and thus improve treatment adherence and clinical outcomes.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.5582/ddt.2022.01071 | DOI Listing |
J Clin Med
January 2025
Department of Cardiac Surgery, HonorHealth, 10210 N 92nd St, Scottsdale, AZ 85258, USA.
Steel wires are often inadequate for sternal closure for patients at high risk of sternal complications. This study compares a novel sternal closure system to conventional steel wires to assess its potential to reduce sternal complication rates and improve clinical outcomes. A retrospective study was conducted on 300 consecutive patients undergoing cardiac surgery via median sternotomy.
View Article and Find Full Text PDFPolymers (Basel)
January 2025
Sinopec Key Laboratory of Research and Application of Medical and Hygienic Materials, SINOPEC (Beijing) Research Institute of Chemical Industry Co., Ltd., No. 14 Beisanhuan Donglu, Chao Yang District, Beijing 100013, China.
Disentangled ultra-high-molecular-weight polyethylene (-UHMWPE) solves the problem of the difficult processing of traditional UHMWPE caused by entanglements between molecular chains. In this review, we look into the innovative realm of nascent disentangled UHMWPE, concentrating on the recent advances achieved through the in situ polymerization of ethylene by single-site catalysts. The effect of single-site catalysts and polymerization conditions on the molecular characteristics is discussed in detail from the perspective of mechanism and DFT calculations.
View Article and Find Full Text PDFMed Dosim
January 2025
Department of Radiation Oncology, University of Rochester Medical Center, Rochester, NY.
Purpose: In radiotherapy treatment planning systems, modelling of superficial dose may be aided by a body contour that is, by default, placed at the outermost air-tissue interface. Here we investigate the accuracy of superficial dose calculated using either the default body contour (DBC) or an extended body contour (EBC) compared to radiochromic film measurements made on a slab phantom and an anthropomorphic phantom.
Methods: Depth dose curves in the superficial region of the slab phantom were measured using stacked radiochromic films and irradiated using static beams delivered from varying incident angles.
PLoS One
January 2025
Key Laboratory of Sports Engineering of General Administration of Sport of China, Wuhan Sports University, Wuhan, Hubei Province, China.
Purpose: Previous studies have demonstrated significant biomechanical differences between individuals with chronic ankle instability (CAI) and healthy controls during the Y-balance test. This study aimed to examine the effects of kinesio taping (KT) on lower limb biomechanical characteristics during the Y-balance anterior reach task in individuals with CAI.
Methods: A total of 30 participants were recruited, comprising 15 individuals with CAI and 15 healthy controls.
Sci Rep
December 2024
National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL, 32310, USA.
Plastic damage of REBCO (REBaCuO, where RE=rare earth) coated conductors by screening current stress (SCS) is a significant concern for ultra-high-field superconducting magnets. Indeed, the third Little Big Coil (LBC3), a REBCO magnet that generated a record, high field of 45.5 T, showed wavy plastic damage produced by excess SCS in all pancakes except two made with single-slit conductors having their slit edges pointing inward towards the magnet center.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!