A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrochemical Response of Redox Amino Acid Encoded Fluorescence Protein for Hydroxychloroquine Sensing. | LitMetric

The sudden rise in the demand has led to large-scale production of hydroxychloroquine (HCQ) in the global market for various diseases such as malaria, rheumatic arthritis, and systemic lupus erythematous and prophylactic treatment of early SARS-CoV-2 outbreak. Thorough monitoring of HCQ intake patients is in high demand; hence, we have developed a redox amino acid encoded fluorescent protein-based electrochemical biosensor for sensitive and selective detection of HCQ. This electrochemical biosensor is generated based on the two-electron transfer process between redox amino acid (3,4-dihydroxy-L-phenylalanine, DOPA) encoded bio-redox protein and the HCQ forms the conjugate. The DOPA residue in the bio-redox protein specifically binds with HCQ, thereby producing a remarkable electrochemical response on the glassy carbon electrode. Experimental results show that the developed biosensor selectively and sensitively detects the HCQ in spiked urine samples. The reagent-free bio-redox capacitor detects HCQ in the range of 90 nM to 4.4 µM in a solution with a detection limit of 58 nM, signal to noise ratio of 3:1, and strong anti-interference ability. Real-time screening, quantification, and relative mean recoveries of HCQ on spiked urine samples were monitored through electron shuttling using bio-redox protein and were found to be 97 to 101%. Overall, the developed bio-redox protein-based sensor has specificity, selectivity, reproducibility, and sensitivity making it potentially attractive for the sensing of HCQ and also applicable to clinical research.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9581447PMC
http://dx.doi.org/10.1007/s12010-022-04142-wDOI Listing

Publication Analysis

Top Keywords

redox amino
12
amino acid
12
bio-redox protein
12
hcq
9
electrochemical response
8
acid encoded
8
electrochemical biosensor
8
detects hcq
8
hcq spiked
8
spiked urine
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!